Re: Saniplus capacitor replacement
Glenn Nadeau <[email protected]> Tue, 4 Oct 2022 16:55:27 -0700 (PDT)
| Newsgroups | alt.building.construction |
|---|---|
| Message-ID | <[email protected]> |
On Friday, November 28, 2003 at 10:41:19 AM UTC-5, [email protected] wrote: > My Saniplus, about 4 yrs. old, is just emitting a hum and not pumping. > Having taken the unit apart, there is nothing blocking the blades, etc., = and the > impeller turns freely, so I suspect the capacitor and would like to try > replacing it before contemplating new motors, etc.. > Can anyone tell me where the damn thing is?! The schematic shows it along= side > the pressure chamber, but I can't see it. If it's inside the chamber, how= do I > get at it? > I've taken the membrane off but that doesn't help. > TIA > Tom L Once you remove the membrane, remove the plunger then pry off the cover and= the capacitor and microswitch and motor are under the cover. Take picture = of the 2 wires where the capacitor is attached so you can reference them wh= en putting the wires back. Saniflo has an excellent YouTube video showing t= he entire process.