Re: UNIONS ON GAS PIPE
CFH <[email protected]> Wed, 26 Apr 2023 03:31:58 +0000
| Newsgroups | alt.building.construction |
|---|---|
| Organization | NewsgroupDirect |
| Message-ID | <[email protected]> |
The section that says unions need to be after the appliance shut of valve it talking about appliances. If some one interprets that as unions are prohibited they would be incorrect. No where in the fuel gas code does it say unions are prohibited. The section that talks about piping 403.10 piping joint shall be suitable for the pressure and temperature. If a union is good after a gas valve it is good before. There are unions on meter bars and gas risers. There is a section that states what fittings can be used in concealed locations and unions are not included in the list -- For full context, visit https://www.homeownershub.com/construction/unions-on-gas-pipe-16983-.htm