Re: use of chg-robot and cleaning for HP MSL3040

Winston Sorfleet <[email protected]>
Newsgroups gmane.comp.archivers.amanda.user
Message-ID <[email protected]>
On 2021-11-10 11:47 a.m., David Simpson wrote:
>
> Hi all,
>
> Just wanted to double check the use of /chg-robot/ which im using in
> amanda.conf for an HP MSL3040 SAS tape library.…  that this is indeed
> the right type of /changer-driver/? (I have defined this stanza and
> think it looks ok).
>
Correct, e.g.

define changer HP_G2 {
    tpchanger "chg-robot:/dev/LTOchanger"
    property "tape-device" "0=tape:/dev/nst0"
    property "use-slots" "1-7"
    property "load-poll" "13s poll 5s"
    device-property "LEOM" "TRUE"
}


>
> The other question is around cleaning. Presumably when the library
> itself alerts for cleaning, its up to the admin to fit it in around
> the backup cycle. ThatÂ’s the way im reading the docs at the moment for
> this changer-driver.
>
> thanks
> David
>
>
> -------------
>
> David Simpson - Senior Systems Engineer
>
> ARCCA, Redwood Building,
>
> King Edward VII Avenue,
>
> Cardiff, CF10
> 3NB                                                                              
>
>  
>
> David Simpson - peiriannydd uwch systemau
>
> ARCCA, Adeilad Redwood,
>
> King Edward VII Avenue,
>
> Caerdydd, CF10 3NB
>
>  
>