CVS commit - 0.96.0
Jan Depner <[email protected]>
| Newsgroups | gmane.comp.audio.jamin.devel |
|---|---|
| Message-ID | <1178987720.20799.8.camel@eviltwin> |
* Moved global bypass button next to limiter bypass and made it
a check box
* Global bypass blinks every 1/2 second when on
* Added main output level numeric boxes above output meter
* Added RMS level numeric boxes above output meter
* Added ability to reset single RMS or output peaks in output meter
by clicking in the numeric level boxes
* Added ability to select output/RMS level or output/RMS peak
levels in the numeric level boxes from the preferences dialog
Still need to allow setting of the RMS window size by number of
samples with an associated display of the time window this will create.
Right now the RMS meters are hard-wired to 1000 samples. I'm thinking
that we should limit the RMS window range to between 1000 and 5000
samples. This gives us a time range of between 0.0227 and 0.1134
seconds at 44100Hz and between 0.0104 and 0.0521 seconds at 96000Hz.
Does this sound OK?
Jan
--
Jan 'Evil Twin' Depner
http://myweb.cableone.net/eviltwin69
"Life should NOT be a journey to the grave with the intention of
arriving safely in an attractive and well preserved body, but rather to
skid in sideways, chardonnay in one hand, chocolate in the other, body
thoroughly used up, totally worn out, and screaming 'WOO HOO, what a ride'"
-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express