Re: CVS commit - 0.96.0

Steve Harris <[email protected]>
Newsgroups gmane.comp.audio.jamin.devel
Message-ID <[email protected]>
On 12 May 2007, at 17:35, Jan Depner wrote:

>
>     *  Moved global bypass button next to limiter bypass and made it
>        a check box
>
>     *  Global bypass blinks every 1/2 second when on
>
>     *  Added main output level numeric boxes above output meter
>
>     *  Added RMS level numeric boxes above output meter
>
>     *  Added ability to reset single RMS or output peaks in output  
> meter
>        by clicking in the numeric level boxes
>
>     *  Added ability to select output/RMS level or output/RMS peak
>        levels in the numeric level boxes from the preferences dialog
>
>
>     Still need to allow setting of the RMS window size by number of
> samples with an associated display of the time window this will  
> create.
> Right now the RMS meters are hard-wired to 1000 samples.  I'm thinking
> that we should limit the RMS window range to between 1000 and 5000
> samples.  This gives us a time range of between 0.0227 and 0.1134
> seconds at 44100Hz and between 0.0104 and 0.0521 seconds at 96000Hz.
> Does this sound OK?

I think we should offer the config in milliseconds, and correct for  
the sample rate. Just incase someone opens an existing session and  
runs it at a different clock rate.

- Steve

-------------------------------------------------------------------------