Re: CVS commit - 0.96.0
Steve Harris <[email protected]>
| Newsgroups | gmane.comp.audio.jamin.devel |
|---|---|
| Message-ID | <[email protected]> |
On 12 May 2007, at 17:35, Jan Depner wrote: > > * Moved global bypass button next to limiter bypass and made it > a check box > > * Global bypass blinks every 1/2 second when on > > * Added main output level numeric boxes above output meter > > * Added RMS level numeric boxes above output meter > > * Added ability to reset single RMS or output peaks in output > meter > by clicking in the numeric level boxes > > * Added ability to select output/RMS level or output/RMS peak > levels in the numeric level boxes from the preferences dialog > > > Still need to allow setting of the RMS window size by number of > samples with an associated display of the time window this will > create. > Right now the RMS meters are hard-wired to 1000 samples. I'm thinking > that we should limit the RMS window range to between 1000 and 5000 > samples. This gives us a time range of between 0.0227 and 0.1134 > seconds at 44100Hz and between 0.0104 and 0.0521 seconds at 96000Hz. > Does this sound OK? I think we should offer the config in milliseconds, and correct for the sample rate. Just incase someone opens an existing session and runs it at a different clock rate. - Steve ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/