Bacula or Drive problem?
Udo Kaune <[email protected]>
| Newsgroups | gmane.comp.bacula.user |
|---|---|
| Message-ID | <[email protected]> |
Am 15.06.25 um 10:19 schrieb Dr. Thorsten Brandau via Bacula-users:
>
> Udo Kaune schrieb am 13.06.25 um 23:47:
>> Hi Thorsten,
>>
>> Did you reboot the box recently and did by any chance your devices get reordered?
>> What does lsscsi -g show and does that correspond to your bacula-sd.conf entries?
>>
>> Best regards, Udo
>>
> Hi Udo,
>
> yes, I regularily reboot the system for maintenance:
>
> sudo lsscsi -g
> [0:0:0:0] disk Areca ARC-1883-VOL#000 R001 /dev/sda /dev/sg0
> [0:0:0:1] disk Areca ARC-1883-VOL#001 R001 /dev/sdb /dev/sg1
> [0:0:0:2] disk Areca Data6 R001 /dev/sdc /dev/sg2
> [0:0:0:4] disk Areca VOL_Data4 R001 /dev/sdd /dev/sg3
> [0:0:16:0] process Areca RAID controller R001 - /dev/sg4
> [1:0:0:0] enclosu ATTO VirtualSES 0001 - /dev/sg6
> [1:0:1:0] tape IBM ULTRIUM-HH9 R3G1 /dev/st0 /dev/sg7
> [1:0:1:1] mediumx BDT FlexStor II 6.21 /dev/sch0 /dev/sg8
>
> That looks very susual and it worked in the last months with sg7
> Now, just for the fun of it I used mtx -f /dev/sg8 status additionally and got:
|In Debian if you need a consistent device for the changer across reboots you will need to setup some udev rules:
udevadm info -q all -a -n /dev/sch0 | grep -e vendor -e model
ATTRS{model}=="FlexStor II "
ATTRS{vendor}=="BDT "
...
udevadm info -q all -a -n /dev/sg8 | grep -e vendor -e model
ATTRS{model}=="FlexStor II "
ATTRS{vendor}=="BDT "
...
cat > /etc/udev/rules.d/80-tape-autochanger-devices.rules <<EOL
#scsi generic device name
SUBSYSTEM=="scsi_generic", ATTRS{vendor}=="BDT ", ATTRS{model}=="FlexStor II ", SYMLINK+="changer0"
# block device name
# SUBSYSTEM=="block", DRIVERS=="mt", ATTRS{vendor}=="BDT ", ATTRS{model}=="FlexStor II ", SYMLINK+="changer0_block"
#
EOL
Beware of the attributes containing white space. There is no need for a changer block device for now. After reboot you should be able to use /dev/changer0 in your bacula-sd.conf autochanger setup and it will be consistent.