>I have installed 'Electric' version 8.04. This is really amazing!
>I would like to try on some of the analog blocks. Can I use 4
>terminal MOS devices in 'Electric' as is often the case where the
>body is not tied to the source in analog circuits? What would be
>limitations? (The manual says 'Electric does not keep track of the
>connectivity of the substrate connection of layout transistors.')
You can place 4-terminal transistors from the schematics
technology. Their use may or may not work, depending on the
simulation environment. For Analog simulators such as Spice, all 4
connections are written, and it will work fine. For some digital
simulators, the bias connection is ignored, and so you may have
trouble if you are doing non-digital wirings.
> Also what would be the case when the body of MOS is not tied to
> the substrate? How is it handled in Electric?
In such a case, the Spice netlist will be incomplete, and other
netlists will not notice.