Re: IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION

"pjfarley3-/[email protected] [hercules-390]" <[email protected]>
Newsgroups gmane.comp.emulators.hercules390.general
Message-ID <[email protected]>
I agree with Mike, please try running Hercules on your new system with V3.13.  I have found it very stable on my Win10Pro i7 machine.

 

 Wait state 064 is documented here at IBM KC:
 

 https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ieah700/m015362.htm https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ieah700/m015362.htm

 

 According to that page your "reason code" is "009", a program check interruption occurred during NIP processing.
 

 Before trying to chase down why NIP gets a program check, please try the newer Hercules version on your new system, that may be the entire answer.
 

 HTH
 

 Peter

---In [email protected], <mikestramba@...> wrote :

 Have you tried Hercules 3.13 ? :
 
 http://www.hercules-390.eu http://www.hercules-390.eu
 
 Mike
 
 On 3/18/19, rixhawg@... mailto:rixhawg@... [hercules-390]
 <[email protected] mailto:[email protected]> wrote:
 > I know that this issue was discussed and closed back in 2016, but after
 > reviewing all of the posts and comments and applying the fixes to the
 > configuration files I am still at a loss.
 >
 >
 > My issue is this. I recently upgraded my workstation from a motherboard
 > that only supported 8gig of memory to one that supports 32gig. It's running
 > an I5 4core Intel cpu running Windows 7 Professional. Both systems have the
 > Hyperion 4.1 version of Hercules and I am using the same configuration file
 > for both systems. On my old 8gig system, my z/OS 1.10 system IPLs fine and
 > I have been running it for a couple of months on the old PC. However, when
 > I run the same exact OS and configuration file on the new 32gig system, I
 > encounter the error mentioned in previous posts. See below for the error:
 >
 >
 > IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNP10 INITIALIZATION
 >
 >
 >
 > I can run the system using Hercules 3.07 fine on the new 32gig PC, but
 > would like to use the latest version. Any ideas?
 >
 >
 > Rick
 >
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.