Re: Hercules consol problem
| Newsgroups | gmane.comp.emulators.hercules390.general |
|---|---|
| Message-ID | <CAPcd4G9LXD02PAsNO5nBO9XjyG2LMRX=u=Xeyor5KK6rxTA6kA@mail.gmail.com> |
Hey Jon, Hercules connects the terminals lowest available address first. When a telnet session is connected after IPL, the console addresses are no longer available and so the first non-console address gets connected. " If you do not specify a suffix in your telnet client software (or your software does not allow it), then your client will be connected to the first available 1052 or 3215 device for which it is eligible." Joe On Tue, Aug 6, 2019 at 12:53 PM Jon Perryman jperryma-yBeKhBN/[email protected] [hercules-390] <[email protected]> wrote: > > > If I understood Joe's solution correctly, the address (400) was correct. > The problem was connecting the terminal after IPL will leave the console > offline. The solution was to connect the terminal before IPL. > > Jon. > > On Tuesday, August 6, 2019, 07:16:19 AM PDT, 'Fernando M. Roxo da Motta' > [email protected] [hercules-390] <[email protected]> wrote: > > > > > On 06 Aug 2019 09:45:21 +0000, "[email protected] [hercules-390]" > <[email protected]> wrote: > > > Ivan, > > thank you for your Reply, but it was exactly as the hint from Joe > > was. I did'nt Connect the consoles bevor IPL. Now I could IPL my > > System without Problems and can make my Education on TSO. > > I don't know if this can help. > > X3270 terminal emulator has the capability to set the desired terminal > address at activation: > > x3270 -model 3279 -once -title Console -once [email protected]:3270 > > That "011@" is the terminal address to connect to. This can allow to > open the terminals in whatever order and get it connected where desired. > > > >