Re: MVT COBOL under MVS3.8j.

"Joe Monk [email protected] [H390-MVS]" <[email protected]>
Newsgroups gmane.comp.emulators.hercules390.mvs
Message-ID <CAPcd4G93GaECmxMBYyR4+2DsjZN-CokpFbURi6PGxe5C2WCE=A@mail.gmail.com>
Peppe,

Remember, this compiler doesnt know about VS!

Joe

On Sat, Sep 14, 2019 at 4:59 AM Giuseppe Vitillaro giuseppe-yuD/ahkh7LvrZ44/[email protected]
[H390-MVS] <[email protected]> wrote:

>
>
> On Sat, 14 Sep 2019, Giuseppe Vitillaro giuseppe-yuD/ahkh7LvrZ44/[email protected] [H390-MVS]
> wrote:
>
> > On Fri, 13 Sep 2019, 'Shelby Beach' [email protected] [H390-MVS]
> wrote:
> >
> >> Whoa, this gives me an idea... Peppe, why don't you try running the
> compiler
> >> on MVS as V=R.
> >>
> >> Shelby
> >
> Ok, I figured out why wasn't running in a small region,
> the SYSLIB BLKSIZE was too large ;-(
>
> Now it would run in 128K, it does for V=V,
> but for V=R I get:
>
> JOB 617 $HASP303 COB1 RE-ENQUEUED AND HELD
> $HASP309 INIT 1 INACTIVE ******** C=A
> STC 1750 IEF090E PROTECT KEY UNAVAILABLE COB1 PLACED ON HOLDQ
>
> Now, it looks COBOL compiler doesn't like to run in V=R?
>
> Peppe.
> 
>