Re: Re: Help with IPL problem
| Newsgroups | gmane.comp.emulators.hercules390.mvs |
|---|---|
| Message-ID | <[email protected]> |
Thanks....Worked.... On 9/16/2019 3:10 PM, ''Fish' (David B. Trout)' [email protected] [H390-MVS] wrote: > > [...] > > Try adding the cu=3990-6 to your dasd definitions > ^^^^^^ > ^^^^^^ > [...] > > HHC00416E 0:5003 CKD file c:/hdasd/uzosf1: > > control unit 3390-6 not found in dasd table > ^^^^^^ > ^^^^^^ > > 3390-6 != 3990-6 > > 3390-6: dasd model 6 > 3990-6: control unit model 6 > > cu=(dasd model 6) WRONG > cu=(control unit model 6) RIGHT > > -- > "Fish" (David B. Trout) > Software Development Laboratories > http://www.softdevlabs.com > mail: [email protected] > > --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus