If you change the current sixpack.conf file from

# Display Terminals... these are defined in DMKRIO as 3278-4s.
02C0 3270
02C1 3270
02C2 3270

to

# Display Terminals... these are defined in DMKRIO as 3278-4s.
02C0.7 3270 MOD4

Then use MOD4 as the LUname to connect to in your emulator, you should get the next available 3278-4.  No need to redo DMKRIO.

Bob

--- In [email protected], Mike Stramba <mikestramba@...> wrote:
>
> Bob,
> 
> Are you getting more than 24 lines with mod 4?
> 
> Did you alter / re-assemble your DMKRIO / regen  CP ?
> 
> Mike
> 
> On 8/12/10, Robert O'Hara <rohara@...> wrote:
> > Hey, it works, just like a real computer!  I will so update the SixPack.
> >
> > Thanks Ivan.
> >
> > Bob
> >
> > --- In [email protected], Ivan Warren <ivan@> wrote:
> >>
> >> Robert O'Hara wrote:
> >> > I think I have DMKRIO somewhat understood.  Right now I have 16 3277-2s
> >> > starting at 0C0, and 7 3278-4s starting at 1C0.
> >> >
> >> > If I connect using the wc3270 emulator defined as a model 2, it happily
> >> > connects at 0C0, and if I run a second copy, it connects at 0C1, and so
> >> > on.  This is working as I expect.
> >> >
> >> > But when I try to connect using the wc3270 emulator defined as a model
> >> > 4, it tries to connect at 0C0 (or whatever the next available address
> >> > is) and I never get the VM logo screen because (I assume) I am trying to
> >> > connect a 3278-4 to a 3277-2 port.
> >> >
> >> > If I explicitly specify the address (i.e. 1C0) then the 3278-4 connects
> >> > correctly.
> >> >
> >> > Is there any way to set things up so I get the "next one that fits" 3270
> >> > connection?
> >> >
> >> > Bob
> >> >
> >>
> >> You may want to try the group name capability of the 3270 connector :
> >>
> >> http://www.hercules-390.org/hercconf.html#3270
> >>
> >> so if you do something like :
> >>
> >> 0C0.16 3270 SMALL
> >> 161.16 3270 LARGE
> >>
> >> And you connect with a parameter of "SMALL" for your 24x80 terminals and
> >> "LARGE" for your model 4s, it should work.
> >>
> >> --Ivan
> >>
> >
> >
> >
> >
> > ------------------------------------
> >