Re: Compile and run later

Mike Stramba <[email protected]>
Newsgroups gmane.comp.emulators.turnkey-mvs
Message-ID <[email protected]>
>There is a mechanism for "implicit" running, e.g. anything in
SYS1.LINKLIB, SYS2.LINKLIB, but I'm not sure where that's setup.

I meant to say, I'm not sure how you setup *additional* libraries to
be searched implicitly, in addition to SYS1.LINKLIB ..SYS1.LINKLIB

On 5/19/10, Mike Stramba <[email protected]> wrote:
> 1) RPF won't let you edit / view certain types (not sure which) of
> datasets.
> The manual says "View not available, The specified dataset is not a
> card image library.", which I would *think* means 80 byte records (for
> 'card image'), but it *does* let me view a dataset with 121 Lrecl)
>
> Anway,
> At the TSO promp (or RPF option 6 (TSO), use the PDS command
>
> PDS HUDSON.LINKLIB
> d(isplay)
> **** should see 'GRID' ... and any other members you've compiled **
> end   **** exit PDS
>
> call 'hudson.linklib(grid)'
>
> There is a mechanism for "implicit" running, e.g. anything in
> SYS1.LINKLIB, SYS2.LINKLIB, but I'm not sure where that's setup.
>
> In "Intro to Zos Basics", page 496 "Search order for programs",
> http://tinyurl.com/23z7as4
>
> it says
> "5. Libraries in the linklist, as specified in PROGxx and LNKLSTxx
> By default, the linklist begins with SYS1.LINKLIB, SYS1.MIGLIB, and
> SYS1.CSSLIB. However, you can change this order using SYSLIB in
> PROGxx and add other libraries to the linklist concatenation. The system
> must bring modules found in the linklist into private area virtual
> storage before
> the programs can run.
> The default search order can be changed by specifying certain options on
> the
> macros used to call programs. The parameters that affect the search order
> the
> system will use are EP, EPLOC, DE, DCB, and TASKLIB. For more information
> about these parameters, see the topic about the search for the load module
> in
> z/OS MVS Programming: Assembler Services Guide. Some IBM subsystems
> (notably CICS and IMS) and applications (such as ISPF) use these facilities
> to
> establish other search orders for programs."
>
> I don't know what relevance that has to Turnkey (MVS38j)
>
> You can also add a CLIST in either Hudson.CMDPROC or SYS1.CMDPROC :,
> just putting the same command as above :
>
> Just add a member called whatever, e.g.   RUNGRID, or even just GRID
>
> call 'hudson.linklib(grid)'
>
> Then you'll be able to just type GRID at the TSO prompt.
>
> Mike
>
>
> On 5/19/10, Ron Hudson <[email protected]> wrote:
>>>
>>> I susspected It was something like that - I now have a new PDS (I think
>> it's a PDS)
>> but I cant 'E' it in RPF menu 3.4 to verify it has a member named "Grid"
>>
>>    HUDSON.DATA.DATA           PUB002 10.138 PO   FB      80  3120   1
>> 300
>> 299
>>    HUDSON.FORT.FORTH          PUB000 10.138 PO   FB      80  3120   1
>> 30    5
>>    HUDSON.LINKLIB             MVSCAT 10.138 PO   U        0 32760   1
>> 45   44
>>    HUDSON.PROG.PL1            PUB002 10.133 PO   FB      80  3120   1
>> 150
>> 149
>>
>> So, How do I run it now?
>>
>