Re: Re: NUMCPU >1 = IEE331A EXCESSIVE DISABLED SPIN LOOP DETECTED
Gerhard Postpischil <[email protected]>
| Newsgroups | gmane.comp.emulators.turnkey-mvs |
|---|---|
| Message-ID | <[email protected]> |
On 5/23/2010 4:04 AM, Mike Stramba wrote: > How do you do that from the config file? I could have sworn I saw a parameter in the conf description, but I just reread the user guide, and couldn't anything. But the CPU specification option for a controller is also available as part of an MVS sysgen? (it's been a long time) I got a reminder about the CPU vs I/O processor on our 4381. We had four channels on each CPU, running SP 1.3, and I made the mistake of letting one of my employees handle a move, device configuration, and sysgen. He know that load balancing was important, so he defined our NCR/Comten 3695 on channel 0, but on CPU 2. So whenever a task requested an I/O, it was routed to CPU 0 for processing. CPU 0 shipped the request for the Comten to CPU 2, which issued the I/O. The response came back on CPU 2, which had to ship it to 0, ad nauseam. The problem came to my attention because on the first day of production, user's remote JES lines kept dropping on time-out errors. I switched cables to CPU 0, ran a quick I/O gen, and the problem disappeared. And I was wrong about running with 2 CPUs. I set the number in the conf file, changed it in HercGUI, and IPLed (twice so far) then wrote a little program to format the LCCA and PCCA, only to find out I only have one CPU active - so I'll go back into my corner and work on Wylbur... Gerhard Postpischil Bradford, VT