https://github.com/krb5/krb5/commit/2b34a007461065e0cab4490dfe1ae5ddd10da67b
commit 2b34a007461065e0cab4490dfe1ae5ddd10da67b
Author: Simo Sorce <[email protected]>
Date: Thu May 19 12:27:40 2022 -0400
Read GSS configuration files with mtime 0
There is at least one case (with flatpaks) where configuration files
in the special read-only /etc all have an mtime of 0. Using an
initial last modified time of 0 in g_initialize.c causes these files
to never be read.
Change the initial high value to the be the "invalid" value
(time_t)-1. Since the C and POSIX standards do not require time_t to
be signed, special-case the checks in load_if_changed() and
updateMechList() to treat all mod times as newer than -1.
[[email protected]: edited commit message; slightly modified approach]
ticket: 9060 (new)
target_version: 1.20
tags: pullup
src/lib/gssapi/mechglue/g_initialize.c | 11 ++++++-----
1 file changed, 6 insertions(+), 5 deletions(-)
diff --git a/src/lib/gssapi/mechglue/g_initialize.c b/src/lib/gssapi/mechglue/g_initialize.c
index b26262d69..22f6c615c 100644
--- a/src/lib/gssapi/mechglue/g_initialize.c
+++ b/src/lib/gssapi/mechglue/g_initialize.c
@@ -93,7 +93,7 @@ static void free_mechSet(void);
static gss_mech_info g_mechList = NULL;
static gss_mech_info g_mechListTail = NULL;
static k5_mutex_t g_mechListLock = K5_MUTEX_PARTIAL_INITIALIZER;
-static time_t g_confFileModTime = (time_t)0;
+static time_t g_confFileModTime = (time_t)-1;
static time_t g_confLastCall = (time_t)0;
static gss_OID_set_desc g_mechSet = { 0, NULL };
@@ -469,9 +469,9 @@ load_if_changed(const char *pathname, time_t last, time_t *highest)
mtime = check_link_mtime(pathname, &mtime);
if (mtime == (time_t)-1)
return;
- if (mtime > *highest)
+ if (mtime > *highest || *highest == (time_t)-1)
*highest = mtime;
- if (mtime > last)
+ if (mtime > last || last == (time_t)-1)
loadConfigFile(pathname);
}
@@ -482,7 +482,7 @@ static void
loadConfigFiles()
{
glob_t globbuf;
- time_t highest = 0, now;
+ time_t highest = (time_t)-1, now;
char **path;
const char *val;
@@ -522,7 +522,8 @@ updateMechList(void)
#if defined(_WIN32)
time_t lastConfModTime = getRegConfigModTime(MECH_KEY);
- if (g_confFileModTime >= lastConfModTime)
+ if (g_confFileModTime >= lastConfModTime &&
+ g_confFileModTime != (time_t)-1)
return;
g_confFileModTime = lastConfModTime;
loadConfigFromRegistry(HKEY_CURRENT_USER, MECH_KEY);