Re: 'Machine ID' underspecified?

Zeeshan Ali <[email protected]>
Newsgroups gmane.comp.freedesktop.dbus
Message-ID <CAAa3hFPY35Fc3qiDZ6V3uGYopO+NS9Re4JJ=Z8_=S=v4Mbqkbg@mail.gmail.com>
Hi,

On Sun, 6 Dec 2020 at 19:07, Filipe Laíns <[email protected]> wrote:
>
> On Sun, 2020-12-06 at 16:31 +0100, Zeeshan Ali wrote:
> > Hello,
> >
> > On Sun, 6 Dec 2020 at 15:57, Filipe Laíns <[email protected]> wrote:
> > >
> > > On Sun, 2020-12-06 at 13:03 +1300, Lawrence D'Oliveiro wrote:
> > > > On Sat, 05 Dec 2020 15:34:31 +0000, Thomas Kluyver wrote:
> > > >
> > > > > The standard org.freedesktop.DBus.Peer interface
> > > > > (
> > > > > https://dbus.freedesktop.org/doc/dbus-specification.html#standard-interfaces-peer
> > > > > ) defines a GetMachineId method. The spec says that this returns a
> > > > > UUID which "must be the same for all processes on a single system at
> > > > > least until that system next reboots."
> > > > >
> > > > > ...
> > > > >
> > > > > I looked into the code for the reference implementation. On Unix, it
> > > > > gets the ID from a compile-time configurable file
> > > > > (/var/lib/dbus/machine-id on my system) with a hardcoded fallback to
> > > > > /etc/machine-id:
> > > >
> > > > Seems like libdbus is going further than the spec requires, by defining
> > > > a value that persists across reboots. That doesn’t seem to be necessary
> > > > for the example use cases described in the spec.
> > >
> > > Right, but the problem is that the spec forces this UUID to be the same for
> > > all
> > > processes but does not defines how that processes should get that ID.
> > > So, how should a client exposing an interface get the correct UUID to send
> > > if
> > > there is no standard way to do it? In my implementation I could just mimic
> > > what
> > > libdbus does, but that could effectively change anytime, and might not be
> > > what
> > > other implementations do.
> >
> > But is that really an issue? Is there a use case of peers connecting
> > to more than 1 broker? As long as the ID is fixed for the same machine
> > for the same broker, should there be any problems?
> >
> > >
> > > Cheers,
> > > Filipe Laíns
>
> The problem isn't the ID given by the broker, but by the ID given by the
> processes exposing interfaces. These processes can be running on a different
> machine than the broker, so they can't ask the broker for the machine ID, for
> eg.
>
> See https://github.com/FFY00/dbus-objects/commit/2c5f19ad3ef26c8bae163985a56e4dc8a35482cb#r44622287
>
> The spec must define a way for the machine prefix to be fetched/calculated,
> otherwise it is an implementation detail and this spec feature does not hold any
> value at all.

Right, I see your point. FWIW the spec does admit that it's not always
possible to implement persistence of UUID across reboots:

"This UUID must be the same for all processes on a single system at
least until that system next reboots. It should be the same across
reboots if possible, but this is not always possible to implement and
is not guaranteed."

-- 