General question about RadSec implementation on FR 3.2.x

<[email protected]>
Newsgroups gmane.comp.freeradius.user
Message-ID <[email protected]>
Hi guys

I know, there is a documentation page about RadSec: https://www.freeradius.org/documentation/freeradius-server/3.2.8/howto/protocols/proxy/enable_radsec.html

But I have some general questions about the RadSec implementation on FR 3.2.x, which I think are not answered in the above documentation page:


1. When I want to proxy RADIUS requests to other RADIUS servers over RadSec (TLS/2083):

a) do I have to configure the home servers in /etc/freeradius/sites-enabled/tls as well, only in the tls file or only in the proxy.conf?

--> I did a test with configuring them only in /etc/freeradius/proxy.conf and the requests were proxied over TLS/2083 to the configured RADIUS proxy servers:

home_server xyz-TLS {
        type = auth+acct
        ipaddr = 1.2.3.4
        proto = tcp
        port = 2083
        secret = radsec
        tls {
                private_key_file = ${certdir}/radsec.key
                certificate_file = ${certdir}/radsec.pem
                ca_file = ${cadir}/radsec-ca.pem
                fragment_size = 8192
        }
        response_window = 20
        zombie_period = 40
        status_check = status-server
        check_interval = 30
        num_answers_to_alive = 3
}

b) what about a mixed deployment, where some of the RADIUS proxy / home servers are accessed over RADIUS (UDP/1812) and some others are access over RadSec (TCP/2083)?


2. When I want to answer RADIUS requests from other RADIUS proxy servers over RadSec (TCP/2083):

a) do I have to configure the clients in /etc/freeradius/sites-enabled/tls as well or only in the tls file? If only in the tls file, I can remove them from the clients.conf file, correct?

b) same as 1.a), what about a mixed deployment; some RADIUS clients are RADIUS (UDP/1812), some are RadSec (TCP/2083)?

Thanks and regards
Dominic
_________________________________
Universität Bern
Abteilung Informatikdienste

Dominic Stalder
Network Engineer

Hochschulstrasse 6
CH-3012 Bern
Tel. +41 (0)31 684 38 18
[email protected]<mailto:[email protected]>
www.id.unibe.ch
_________________________________
-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.