Re: Maxinum Inbound phone support
Stephen Barclay <[email protected]> Thu, 05 Jul 2007 08:38:21 -0500
| Newsgroups | gmane.comp.gnu.bayonne.devel |
|---|---|
| Message-ID | <[email protected]> |
andrew wong wrote: > Dear all, > > We're setting up IVR/Call center server with Bayonne and recently we just > did a 16-way parallel call testing and the result is quite > disappointed. e.g. > great delay, > the ccscript hang after a few minutes, user A's press button affected > user > B, etc. > > I know that the main course maybe the configuration/ccscript and driver > problem since we're > using China made Synway telephony broads. Just hope to ask if there > is any > successful case > of using Bayonne and the maximum numbers of concurrent call experienced. > > Thanks very much! > > Andrew > _______________________________________________ > Bayonne-devel mailing list > [email protected] > http://lists.gnu.org/mailman/listinfo/bayonne-devel Andrew, Just as a benchmark I use Bayonne 1.2.15 and Dialogic (Global Call) and I have 312 ports per machine and can get to 80% capacity.. This is all outbound dialing to customers. We dial out, do answer detection, play message and elicit dtmf responses and store to database.. To get past the 10 T1 limit I had to tweak LiS (increase the number of fifo's) otherwise code would die creating pipe's... Respectfully, Stephen Barclay stephen 'at' call-em-all.com