Re: SANE with Samsung SCX-4x21F Getting IO Error

sqe6nouc--- via sane-devel <[email protected]>
Newsgroups gmane.comp.graphics.scanning.sane.devel
Message-ID <[email protected]>
Hello,

here are the outputs

  ➜  scanimage -L
[17:17:44.369262] [sanei_debug] Setting debug level of xerox_mfp to 50.
[17:17:44.369303] [xerox_mfp] sane_init: Xerox backend (build 13), 
version != null, authorize != null
[17:17:44.373228] [xerox_mfp] sane_xerox_mfp_get_devices: 0x7ffd8c696620, 0
[17:17:44.373311] [xerox_mfp] list_one_device: libusb:003:026
[17:17:44.373319] [xerox_mfp] usb_dev_open: open 0x62e3c9d43a50
[17:17:44.374920] [xerox_mfp] :: dev_command(INQUIRY[0x12], 70)
[17:17:44.390739] [xerox_mfp] [70] a8 00 43 10 53 41 4d 53 55 4e 47 20 
4f 52 49 4f 4e 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 
11 3f 06 29 00 00 27 d8 00 00 41 a0 00 01 2f 00 00 01 00 00 00 00 41 a0 
00 00 36 d8 01 1d 05 05 00...
[17:17:44.390781] [xerox_mfp] dev_inquiry: found SAMSUNG/ORION
[17:17:44.390795] [xerox_mfp] JPEG compression enabled
[17:17:44.390806] [xerox_mfp] usb_dev_close: closing dev 0x62e3c9d43a50
device `xerox_mfp:libusb:003:026' is a SAMSUNG ORION multi-function 
peripheral
device `smfp:usb;04e8;3419;SERIALNUMBERREDACTED.' is a Samsung SCX-4x21 
Series on USB Scanner

  ➜ SANE_DEBUG_XEROX_MFP=50 scanimage  -o testscan20230117-1.tiff -d 
"xerox_mfp:libusb:003:026"
[17:18:17.986006] [sanei_debug] Setting debug level of xerox_mfp to 50.
[17:18:17.986081] [xerox_mfp] sane_init: Xerox backend (build 13), 
version != null, authorize != null
[17:18:17.992905] [xerox_mfp] sane_xerox_mfp_open: 'libusb:003:026'
[17:18:17.992936] [xerox_mfp] sane_xerox_mfp_get_devices: (nil), 1
[17:18:17.993012] [xerox_mfp] list_one_device: libusb:003:026
[17:18:17.993019] [xerox_mfp] usb_dev_open: open 0x6543bfa9da50
[17:18:17.994769] [xerox_mfp] :: dev_command(INQUIRY[0x12], 70)
[17:18:18.996855] [xerox_mfp] usb_dev_request: sanei_usb_read_bulk: 
Error during device I/O
[17:18:18.996938] [xerox_mfp] dev_command: dev_request: Error during 
device I/O
[17:18:18.996949] [xerox_mfp] usb_dev_close: closing dev 0x6543bfa9da50
[17:18:18.999199] [xerox_mfp] list_one_device: 
dev_inquiry(libusb:003:026): Error during device I/O
scanimage: open of device xerox_mfp:libusb:003:026 failed: Invalid argument

Thank you.

On 2024/01/17 16:35, Ralph Little wrote:
> Hi,
> 
> On Tue, Jan 16, 2024 at 11:14 PM <[email protected] 
> <mailto:[email protected]>> wrote:
> 
>     Hello,
> 
> 
>     Hope you are having a great day. The output from the command as follow:
> 
>       >  ➜ scanimage -L
>       > device `xerox_mfp:libusb:003:023' is a SAMSUNG ORION multi-function
>     peripheral
>       > device `smfp:usb;04e8;3419;SERIALNUMBERREDACTED.' is a Samsung
>     SCX-4x21 Series on USB Scanner
> 
> 
>     I have already tried both and both didn't scan. The result from the
>     previous email is from the xerox_mfp one
> 
>     Thank you very much.
> 
> 
> Could you let us see some diag output from the xerox_mfp backend?
> 
> SANE_DEBUG_XEROX_MFP=50 scanimage  {whatever options you use}
> 
> If there is a *lot* of output, perhaps just send it to me as an attachment.
> 
> Cheers,
> Ralph
> 
>     On 2024/01/17 7:04, Ralph Little wrote:
>      > Hi,
>      >
>      > On 2024-01-14 06:20, sqe6nouc--- via sane-devel wrote:
>      >> Hello,
>      >>
>      >> I am currently trying to get SANE to scan with a Samsung
>     SCX-4x21F MFP
>      >> on Arch Linux.
>      >>
>      >> I have sane 1.2.1-5 and xsane 0.999-6 on kernel 6.6.10-arch1-1 (KDE
>      >> Plasma Wayland) with the following driver packages:
>      >>
>      >> samsung-unified-driver 1.00.39-7
>      >> samsung-unified-driver-common 1.00.39-7
>      >> samsung-unified-driver-printer 1.00.39-7
>      >> samsung-unified-driver-scanner 1.00.39-7
>      >>
>      >> dmesg:
>      >>
>      >> [75005.102178] usb 3-9: new full-speed USB device number 6 using
>     xhci_hcd
>      >> [75005.245210] usb 3-9: New USB device found, idVendor=04e8,
>      >> idProduct=3419, bcdDevice= 1.00
>      >> [75005.245235] usb 3-9: New USB device strings: Mfr=1, Product=2,
>      >> SerialNumber=3
>      >> [75005.245245] usb 3-9: Product: SCX-4x21 Series
>      >> [75005.245248] usb 3-9: Manufacturer: Samsung
>      >> [75005.245249] usb 3-9: SerialNumber: <serial redacted>.
>      >> [75005.926529] usblp 3-9:1.1: usblp0: USB Bidirectional printer
>     dev 6
>      >> if 1 alt 0 proto 2 vid 0x04E8 pid 0x3419
>      >> [75005.926577] usbcore: registered new interface driver usblp
>      >>
>      >> Error I am getting:
>      >> Failed to start scanner: Error during device I/O
>      >>
>      >> If I wait a bit then click scan again, it starts scanning,
>     however the
>      >> scan head stuck at the end of the flatbed and XSane hangs for a bit
>      >> then the following error is shown:
>      >> Error during read: Error during device I/O
>      >>
>      >> After this, the scan head is still stuck at the end of the flatbed
>      >>
>      >> Any help would be appreciated. Thank you.
>      >>
>      >
>      > I wonder why the xerox_mfp backend wouldn't provide you with
>     support for
>      > this device. You have a very recent version of the backends and
>     it is
>      > supposed to be supported.
>      > Could you show us the output of:
>      >
>      > scanimage -L
>      >
>      > Cheers,
>      > Ralph
>
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.