Re: SANE with Samsung SCX-4x21F Getting IO Error
sqe6nouc--- via sane-devel <[email protected]>
| Newsgroups | gmane.comp.graphics.scanning.sane.devel |
|---|---|
| Message-ID | <[email protected]> |
Hello, here are the outputs ➜ scanimage -L [17:17:44.369262] [sanei_debug] Setting debug level of xerox_mfp to 50. [17:17:44.369303] [xerox_mfp] sane_init: Xerox backend (build 13), version != null, authorize != null [17:17:44.373228] [xerox_mfp] sane_xerox_mfp_get_devices: 0x7ffd8c696620, 0 [17:17:44.373311] [xerox_mfp] list_one_device: libusb:003:026 [17:17:44.373319] [xerox_mfp] usb_dev_open: open 0x62e3c9d43a50 [17:17:44.374920] [xerox_mfp] :: dev_command(INQUIRY[0x12], 70) [17:17:44.390739] [xerox_mfp] [70] a8 00 43 10 53 41 4d 53 55 4e 47 20 4f 52 49 4f 4e 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 11 3f 06 29 00 00 27 d8 00 00 41 a0 00 01 2f 00 00 01 00 00 00 00 41 a0 00 00 36 d8 01 1d 05 05 00... [17:17:44.390781] [xerox_mfp] dev_inquiry: found SAMSUNG/ORION [17:17:44.390795] [xerox_mfp] JPEG compression enabled [17:17:44.390806] [xerox_mfp] usb_dev_close: closing dev 0x62e3c9d43a50 device `xerox_mfp:libusb:003:026' is a SAMSUNG ORION multi-function peripheral device `smfp:usb;04e8;3419;SERIALNUMBERREDACTED.' is a Samsung SCX-4x21 Series on USB Scanner ➜ SANE_DEBUG_XEROX_MFP=50 scanimage -o testscan20230117-1.tiff -d "xerox_mfp:libusb:003:026" [17:18:17.986006] [sanei_debug] Setting debug level of xerox_mfp to 50. [17:18:17.986081] [xerox_mfp] sane_init: Xerox backend (build 13), version != null, authorize != null [17:18:17.992905] [xerox_mfp] sane_xerox_mfp_open: 'libusb:003:026' [17:18:17.992936] [xerox_mfp] sane_xerox_mfp_get_devices: (nil), 1 [17:18:17.993012] [xerox_mfp] list_one_device: libusb:003:026 [17:18:17.993019] [xerox_mfp] usb_dev_open: open 0x6543bfa9da50 [17:18:17.994769] [xerox_mfp] :: dev_command(INQUIRY[0x12], 70) [17:18:18.996855] [xerox_mfp] usb_dev_request: sanei_usb_read_bulk: Error during device I/O [17:18:18.996938] [xerox_mfp] dev_command: dev_request: Error during device I/O [17:18:18.996949] [xerox_mfp] usb_dev_close: closing dev 0x6543bfa9da50 [17:18:18.999199] [xerox_mfp] list_one_device: dev_inquiry(libusb:003:026): Error during device I/O scanimage: open of device xerox_mfp:libusb:003:026 failed: Invalid argument Thank you. On 2024/01/17 16:35, Ralph Little wrote: > Hi, > > On Tue, Jan 16, 2024 at 11:14 PM <[email protected] > <mailto:[email protected]>> wrote: > > Hello, > > > Hope you are having a great day. The output from the command as follow: > > > ➜ scanimage -L > > device `xerox_mfp:libusb:003:023' is a SAMSUNG ORION multi-function > peripheral > > device `smfp:usb;04e8;3419;SERIALNUMBERREDACTED.' is a Samsung > SCX-4x21 Series on USB Scanner > > > I have already tried both and both didn't scan. The result from the > previous email is from the xerox_mfp one > > Thank you very much. > > > Could you let us see some diag output from the xerox_mfp backend? > > SANE_DEBUG_XEROX_MFP=50 scanimage {whatever options you use} > > If there is a *lot* of output, perhaps just send it to me as an attachment. > > Cheers, > Ralph > > On 2024/01/17 7:04, Ralph Little wrote: > > Hi, > > > > On 2024-01-14 06:20, sqe6nouc--- via sane-devel wrote: > >> Hello, > >> > >> I am currently trying to get SANE to scan with a Samsung > SCX-4x21F MFP > >> on Arch Linux. > >> > >> I have sane 1.2.1-5 and xsane 0.999-6 on kernel 6.6.10-arch1-1 (KDE > >> Plasma Wayland) with the following driver packages: > >> > >> samsung-unified-driver 1.00.39-7 > >> samsung-unified-driver-common 1.00.39-7 > >> samsung-unified-driver-printer 1.00.39-7 > >> samsung-unified-driver-scanner 1.00.39-7 > >> > >> dmesg: > >> > >> [75005.102178] usb 3-9: new full-speed USB device number 6 using > xhci_hcd > >> [75005.245210] usb 3-9: New USB device found, idVendor=04e8, > >> idProduct=3419, bcdDevice= 1.00 > >> [75005.245235] usb 3-9: New USB device strings: Mfr=1, Product=2, > >> SerialNumber=3 > >> [75005.245245] usb 3-9: Product: SCX-4x21 Series > >> [75005.245248] usb 3-9: Manufacturer: Samsung > >> [75005.245249] usb 3-9: SerialNumber: <serial redacted>. > >> [75005.926529] usblp 3-9:1.1: usblp0: USB Bidirectional printer > dev 6 > >> if 1 alt 0 proto 2 vid 0x04E8 pid 0x3419 > >> [75005.926577] usbcore: registered new interface driver usblp > >> > >> Error I am getting: > >> Failed to start scanner: Error during device I/O > >> > >> If I wait a bit then click scan again, it starts scanning, > however the > >> scan head stuck at the end of the flatbed and XSane hangs for a bit > >> then the following error is shown: > >> Error during read: Error during device I/O > >> > >> After this, the scan head is still stuck at the end of the flatbed > >> > >> Any help would be appreciated. Thank you. > >> > > > > I wonder why the xerox_mfp backend wouldn't provide you with > support for > > this device. You have a very recent version of the backends and > it is > > supposed to be supported. > > Could you show us the output of: > > > > scanimage -L > > > > Cheers, > > Ralph >