Fwd: Why do ISO-11898-2 and ARINC 825 never mention split termination?
David Harris <[email protected]>
| Newsgroups | gmane.comp.hardware.bus.can |
|---|---|
| Message-ID | <CAA_RDQVLQX4WhLRq0T-5pkU94zpPi4QE=2tCLf_SKmFbW3qEGQ@mail.gmail.com> |
Our document for the physical layer of OpenLCB (model railroad bus) discusses this, and has some references: http://www.openlcb.org/trunk/specs/CanPhysicalTN.pdf David On Fri, Dec 5, 2014 at 2:36 PM, Corey, Richard <[email protected]> wrote: > ARINC 825 says: > > *3.2.3.1 Network Termination* > A 120 Ω terminating resistor shall be installed on each end of a network > segment for impedance adaptation and to avoid disturbing reflections. > > The ISO specification 11898-2 also refers to termination as “a” resistor. > > Why are single resistors suggested or required instead of split > terminations (two 60 Ohm resistors plus a small capacitor)? > > I thought the split termination was usually preferable and rejected some > high frequency noise from the bus. > > > > I see that minimum distances are required between the last node and a > terminator (1.5 meters), and also between each node (0.5 meters). I’ve > seen that “minimum distance” suggestion elsewhere but seldom noticed any > trouble with desktop setups where these distances are inches or less. (My > definition of “trouble” is any error frames at all, ever, except during > power cycles or hot plugging.) > > We want to use CANbus to connect three adjacent cards inside a box, but it > seems crazy to stuff 3.5 meters of cable inside a small box (and make the > box big enough to fit!). Does everyone who uses CANbus to connect adjacent > cards run big loops of cable around and around the cards to meet this > requirement? > > I don’t have any EE training, so all I understand about the reason for > inter-node distance and node-to-terminator distance is to reduce the risk > of “reflections”. Would it be safe to ignore those rules in an unchanging > network which will never have additional bus segments grafted onto it? > Couldn’t we adjust the distances until all the wave forms are clean, with > distances of a few inches at most, and then lock the geometry down and > never vary it? > > Until I read about “minimum distance requirements”, I never worried about > it in desktop setups. I only got into trouble once. I had a 1-inch CAN > connection between two cards in a cage that “just didn’t work”. I > lengthened the loop and then the traces were clean and error frames went > away, so I stopped worrying. I forget where the terminators were in that > rig (it was 10-12 years ago) but they were either within a few inches of > the two nodes or missing altogether at first. > > > > Rick Corey | Software Engineer | Crane Aerospace & Electronics | Desk > Phone: 425-743-8469 | Cell: 425-345-9954 > > The email account for Crane Aerospace & Electronics, Aerospace Group, has > changed to @craneae.com. > Please update your contact information accordingly. > > > > > > ------------------------------ > > Connect with us on LinkedIn > <http://www.linkedin.com/companies/crane-aerospace-electronics>! > > We value your opinion! How may we serve you better? Please click the > survey link to tell us how we are doing: > http://www.craneae.com/ContactUs/VoiceofCustomer.aspx > > Your feedback is of the utmost importance to us. Thank you for your time. > > Crane Aerospace & Electronics Confidentiality Statement: > The information contained in this email message may be privileged and is > confidential information intended only for the use of the recipient, or any > employee or agent responsible to deliver it to the intended recipient. Any > unauthorized use, distribution or copying of this information is strictly > prohibited and may be unlawful. If you have received this communication in > error, please notify the sender immediately and destroy the original > message and all attachments from your electronic files. > ------------------------------ > >