Re: RE: Will Superposition of error flags desynchronize a active-transmitter passive-receiver bus??

"Christiano SA" <[email protected]> Tue, 21 Aug 2018 18:44:21 +0200
Newsgroups gmane.comp.hardware.bus.can
Message-ID <trinity-cdfe2c75-9ee3-4763-8c09-6da0509f5dac-1534869861099@3c-app-mailcom-lxa09>
> Sent: Monday, August 20, 2018 at 4:34 PM
> From: "John Dammeyer" <[email protected]>
> 
> I'm wondering if you can even create that scenario that you describe.  

Yes, it is possible.
The ISO says:

"""""""""""""""""" (Page 35, ISO11898-1:2015)
An error-active node detecting an error condition shall signal this by sending an active error flag.
The form of the flag violates the rule of bit stuffing or destroy the bit field requiring fixed form.
As a consequence, all other nodes shall detect an error condition too, and shall start sending an error flag.
""""""""""""""""""
--
Archives and useful links: http://groups.yahoo.com/group/CANbus