Re: Help creating remote configuration
Hugo Vacher <[email protected]> Sat, 11 May 2019 21:28:12 -0400
| Newsgroups | gmane.comp.hardware.lirc |
|---|---|
| Message-ID | <CAPfrji-KHwU2_cmX6gz5m_Z18hSgF7PgnSwcppDWmWNyi8871w@mail.gmail.com> |
Hi Bengt,
That last file works perfectly, and following the same model looking at the
signals I got, I was able to come up with a full file:
# IrScrutinizer scrutinized signal
#
# Creating tool: IrScrutinizer version 1.4.3
# Creating user: bengt
# Creating date: Fri May 10 11:12:27 CEST 2019
# Encoding: WINDOWS-1252
#
# Manufacturer: Elunevision
# Model: Luna
# Displayname: Elunevision Luna
# Remotename:
#
begin remote
name IrScrutinizerExport
flags RAW_CODES
eps 30
aeps 100
frequency 0
gap 3423
begin raw_codes
name DOWN
3423 1051 1051 358 1051 358 1051 358
1051 358 358 1051 1051 358 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 1051 358 1051 358
358 1051 1051 358 1051 358 1051 358
358
name UP
3423 1051 1051 358 1051 358 1051 358
1051 358 358 1051 1051 358 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 1051 358 358 1051
1051 358 1051 358 1051 358 358 1051
1051
name STOP
3423 1051 1051 358 1051 358 1051 358
1051 358 358 1051 1051 358 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 358 1051 358 1051
358 1051 358 1051 358 1051 358 1051
358 1051 1051 358 1051 358 358 1051
358 1051 1051 358 1051 358 358 1051
350
end raw_codes
end remote
That works perfectly on every try.
Does that mean the signal is indeed non modulated?
Thanks again for all the help, I will submit the file to
https://sourceforge.net/p/lirc-remotes
Hugo
---------------------------------------------------------------------------------------------
Hugo Vacher, Développeur Web
On Fri, May 10, 2019 at 5:20 AM Bengt Martensson <[email protected]>
wrote:
> On 5/10/19 7:28 AM, Hugo Vacher wrote:
> > Hi Bengt,
> >
> > Thanks for all the help
>
> :-).
>
> > I translated the verbal description you sent, and I am "98% sure"
> that
> > it is correct. Possible the description was not accurate, or the
> > sending
> > has a problem?
> >
> >
> >
> > With no details, no way to help you.
> >
> > What kind of details would help?
>
> In particular the driver and its configuration.
>
> >
> > You appear not to use the non-demodulating receiver, or it is not
> > working. Is is there? Make sure that on IrScrutinizer you have NOT
> > selected Sending hw -> Girs client -> Use receive for capture.
> >
> > Use receive for capture is not checked an I am able to CCapture and
> > decode successfully an old Bell remote I have laying around:
> > protocol = Sharp, device = 1, obc = 22 (frequency 40000 or 39215
> > depending on TV or Bell unit keys)
>
> Ok, that is great news!!
>
> > So to me it seems like everything is working, which would mean that the
> > Elunevision remote indeed has a frequency of 20000, would that change
> > how the file should be written? And how to send the signal?
>
> f=20000 definitely does not mean a frequency of 20kHz detected, but
> rather an error. Sorry, will look into it. I suspect that the actual
> signal might be un-modulated. (This would make "works sometimes,
> unreliably" plausible). I suggest you ask the manufacturer. You may also
> open the device and try to identify the receiver.
>
> Lircd knows how to send non-modulated signals since, IIRC, about two
> years -- IF the driver supports it, which most drivers do not :-\.
>
> > Please make sure that "it" is working correctly when capturing a
> > standard signal, RC5, NEC1, Sony,... Also make sure you can reliably
> > send standard signals.
> >
> > I am able to control my BenQ projector (for which I do not have the
> > remote) using a file from the GlobalCache database (not the exact same
> > remote, so only some keys work).
>
> Again, great news!
>
> >
> > Try to get the (non-demodulating) capture to work reliably (FIRST
> try a
> > standard signal), then we can go from there and modify the protocol.
> > This appears do-able!
> >
> > What would be a good direction to look into? Are there some resource on
> > how to write custom signals? Something that would teach me to write
> > signals manually like you did?
>
> You might like to check out IrpTransmogrifier
> https://github.com/bengtmartensson/IrpTransmogrifier
>
> Try to get this enclosed raw file to work. It contains a cleaned version
> of the signal from your previous DOWN.
>
>
> # IrScrutinizer scrutinized signal
> #
> # Creating tool: IrScrutinizer version 1.4.3
> # Creating user: bengt
> # Creating date: Fri May 10 11:12:27 CEST 2019
> # Encoding: WINDOWS-1252
> #
> # Manufacturer:
> # Model:
> # Displayname:
> # Remotename:
> #
> begin remote
> name IrScrutinizerExport
> flags RAW_CODES
> eps 30
> aeps 100
> frequency 0
> gap 3423
> begin raw_codes
> name DOWN
> 3423 1051 1051 358 1051 358 1051 358
> 1051 358 358 1051 1051 358 358 1051
> 358 1051 1051 358 358 1051 358 1051
> 358 1051 358 1051 358 1051 358 1051
> 358 1051 1051 358 358 1051 358 1051
> 358 1051 358 1051 358 1051 358 1051
> 358 1051 1051 358 1051 358 1051 358
> 358 1051 1051 358 1051 358 1051 358
> 358
> end raw_codes
> end remote
>
>