Problem with ETH PHY Lan8742
Uwe Bonnes <bon-1JbLm1bU5j5ZIx36JBfelj3+ndqKAYMe9FMPySWZwLkb1SvskN2V4Q@public.gmane.org> Wed, 31 Aug 2016 11:38:14 +0200
| Newsgroups | gmane.comp.hardware.microcontrollers.ethernut |
|---|---|
| Message-ID | <[email protected]> |
Hello, while the Phy Lan8742A on the STM32 Discovery Boards works, on my NUCLEO-F746ZG restarting often does not work and on NUCLEO-F767ZI boards even starting only works on rare occasions. One problem I see is the content of the BMCR register after startup. Bits 13/12/8 should be set by the strap option, but often vary. The bits should be captured with reset deasserted, and a quick view with the scope does not show an obvious problem with the reset waveform. Has anybody seen problems with captured strap values on PHYS? Any other ideas how to debug? Thanks -- Uwe Bonnes bon-1JbLm1bU5j5ZIx36JBfelj3+ndqKAYMe9FMPySWZwLkb1SvskN2V4Q@public.gmane.org Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt --------- Tel. 06151 1623569 ------- Fax. 06151 1623305 --------- _______________________________________________ http://lists.egnite.de/mailman/listinfo/en-nut-discussion