Re: [EE]:: Operation of water pumps from Wind Turbines

Dave Tweed <[email protected]>
Newsgroups gmane.comp.hardware.microcontrollers.pic
Organization Embedded Computer Engineering
Message-ID <[email protected]>
Brent Brown wrote:
> On 31 Mar 2025 at 21:33, RussellMc wrote:
> > TL;DR / Summary
> > 
> > Comments on the following are invited - especially the practicality
> > of using DC powered deep well water pumps to allow direct powering
> > of water pumps by wind turbines across a wide range of wind speeds.
> > Of significant uncertainty is the practicality of powering a 1-5 kW
> > range DC powered pump from a highly variable wind source, and the
> > ability to load the turbine close to maximally at all times to prevent
> > damage.
>
> Wind Turbine generates 3-ph AC, directly connected by cable to 3-ph
> induction motor water pump at bottom of well. That part is about as simple
> as it can be other than a fully mechanical drive, and you might argue that
> mechanical could be less reliable. Control system problem is all above
> ground. Gearbox or other dynamically variable connection between WT and
> generator to provide variable frequency/voltage/power to pump.
> (That sounds too simple, needs cleverness, this will be the area that
> makes or beaks the idea).

Wild idea: The transmission from a small vehicle would be appropriate
for this level of power. Subaru makes a rather reliable CVT. Suitable?

-- Dave
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.