Re: [EE]:: Operation of water pumps from Wind Turbines
Dave Tweed <[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.pic |
|---|---|
| Organization | Embedded Computer Engineering |
| Message-ID | <[email protected]> |
Brent Brown wrote: > On 31 Mar 2025 at 21:33, RussellMc wrote: > > TL;DR / Summary > > > > Comments on the following are invited - especially the practicality > > of using DC powered deep well water pumps to allow direct powering > > of water pumps by wind turbines across a wide range of wind speeds. > > Of significant uncertainty is the practicality of powering a 1-5 kW > > range DC powered pump from a highly variable wind source, and the > > ability to load the turbine close to maximally at all times to prevent > > damage. > > Wind Turbine generates 3-ph AC, directly connected by cable to 3-ph > induction motor water pump at bottom of well. That part is about as simple > as it can be other than a fully mechanical drive, and you might argue that > mechanical could be less reliable. Control system problem is all above > ground. Gearbox or other dynamically variable connection between WT and > generator to provide variable frequency/voltage/power to pump. > (That sounds too simple, needs cleverness, this will be the area that > makes or beaks the idea). Wild idea: The transmission from a small vehicle would be appropriate for this level of power. Subaru makes a rather reliable CVT. Suitable? -- Dave