Re: [Ee] Field mill
David VanHorn <[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.pic |
|---|---|
| Message-ID | <CAB115wF_ugfyXkj0ntSrP2ujv3_n5_EARpCi_e+B5GbYv6ixAQ@mail.gmail.com> |
Well, I finally found the odd duck I was looking for. Pasco scientific, PS-3211 It has a 30V bipolar range and communicates by bluetooth by phone app. About $40 on ebay. On Sat, Jun 7, 2025, 3:56 PM David VanHorn <[email protected]> wrote: > " As a hypothetical, if you lay a 100ft pair of 24AWG wires with 300V > insulation on the ground, and lightning strikes one end, what potential > appears on the other end? The potential is with respect to what? And for > how long does the potential exist? Is it likely and/or possible and/or > desirable for the wire to survive a direct strike at one end of the cable?" > > The potential that matters is what ends up across me or my vehicle, or my > equipment. It lasts some milliseconds. It's not likely that the field > mill or the wire would survive a direct hit. 20 to 50 kA does interesting > things. > The old trueism that lightning never strikes the same place twice isn't > really true, but frequently it's somewhat true as "the same place" isn't > there anymore. :) > > I'd urge you to read up on Charles Steinmentz and everything by Martin > Uman. > https://en.wikipedia.org/wiki/Martin_A._Uman > > That copper wire MAY perf it's insulation near the tripod and leave me > with only a few hundred volts, or it may become a plasma channel with > resistance of a few ohms leading the bulk of the strike directly to me. > I'm not willing to risk a copper path that leads directly to me. Even if > only a few hundred volts, it could easily be lethal. It will be rather > humid, and I may well be very wet. > I will also be FAR from any medical support. Heart goes into Vfib and I'm > done. > > > On Sat, Jun 7, 2025 at 4:02 AM Jason White < > [email protected]> wrote: > >> I used to design direct lightning strike circuit protection networks for >> avionics - so I might be biased. >> >> You probably already possess about a dozen ways of getting a reading to >> you >> safely with stuff you have just laying around. >> >> As a hypothetical, if you lay a 100ft pair of 24AWG wires with 300V >> insulation on the ground, and lightning strikes one end, what potential >> appears on the other end? The potential is with respect to what? And for >> how long does the potential exist? Is it likely and/or possible and/or >> desirable for the wire to survive a direct strike at one end of the cable? >> >> Suppose the end of the cable was attached to an indicator: a $5 meter, or >> LED sting, or whatever. What would it take to render said indicator safe >> to >> stand next to and look at? Is it possible for the indicator to be usable >> without ever touching it? Is it likely and/or possible and/or desirable >> for >> the indicator to survive a direct strike at one end of the cable? >> >> I can speculate, but I'd like to hear what you and others think. >> >> I'm genuinely curious about the answers. My intuition tells me one thing, >> but maybe I could be wrong. >> -- >> http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive >> View/change your membership options at >> https://mailman.mit.edu/mailman/listinfo/piclist >> > -- http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at https://mailman.mit.edu/mailman/listinfo/piclist