Re: [EE] Measuring increasing mass over a 1/2 day period
Alan Pearce <[email protected]> Thu, 12 Mar 2026 23:02:02 +0000
| Newsgroups | gmane.comp.hardware.microcontrollers.pic |
|---|---|
| Message-ID | <CAHD638g0g8OQBYAoUxPa2muvMF+_QndVSFK2Lic=_mBSrpVfZA@mail.gmail.com> |
Is the container transparent? I would be tempted to use a reflective optical sensor set up using a calibrated mass of water. That could give you a warning when it is close to the limit, and if you need greater accuracy then the scales come into effect. Does the container have a flexible pipe from the condenser? That would allow you to lift the container to put the scales underneath at the critical time. On Thu, 12 Mar 2026 at 22:31, Chuck Olson <[email protected]> wrote: > Sergio - > > Thanks, that seems fairly easy to do - I'll have to think about it. > > The timeout is usually 2 minutes but can be increased to 5 minutes. > > If I could get around the initial heating period where nothing is > collected, roughly 1.5 hours, possibly the increase in mass would keep > the scale alive ? I will have to try it. > > Chuck > > On Thu, Mar 12, 2026 at 4:45 PM smplx <[email protected]> wrote: > > > > > > > > On Thu, 12 Mar 2026, Chuck Olson wrote: > > > > > The mass in question would start at 263 grams (container mass) and > > > increase over 11+ hours to 4000+ grams (container mass plus about 1 > > > gallon of water). > > > > > > I am trying to measure the distilled water output from a boil of maple > > > sap. I use a Still Spirits Air Still. With the still it's like > > > making candy blindfolded. I can't measure the temperature or the > > > specific gravity of the maple syrup or even see what is happening. > > > > > > But I can measure the input maple sap for mass and sugar > > > concentration. From that I can calculate the amount of maple syrup I > > > should be able to get at a concentration of 67 percent sugar by mass. > > > > > > I do have a kitchen scale which can handle 6000 grams but the problem > > > is that it times out and every subsequent powerup the measurement is > > > zeroed (tare function). I suppose there are AC powered digital scales > > > which might stay on for 11+ hours but would the measurements still be > > > accurate after that time ? > > > > > > The only thing I can think of is to wait until near the end of the > > > boil and then start measuring the mass but that's a hassle trying to > > > put the scale under the container while the still is continuously > > > dripping. > > > > > > Any ideas ? > > > > > > Chuck > > > > I guess the scale has a timeout that resets when the weight changes? If > so > > you just need to upset the weight periodically so that the scale never > > times out. Perhaps a solenoid to tap the scale? > > > > Regards > > Sergio > > -- > > http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive > > View/change your membership options at > > https://mailman.mit.edu/mailman/listinfo/piclist > > -- > http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive > View/change your membership options at > https://mailman.mit.edu/mailman/listinfo/piclist > -- http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at https://mailman.mit.edu/mailman/listinfo/piclist