Re: Recovering from Bad Upgrade
Bryan Armstrong <bryan.armstrong-6tN4nzCoH/[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.tini |
|---|---|
| Message-ID | <[email protected]> |
Patrick Nogara wrote: > I have inserted an RS232 monitor on J6 and I note that I don't see any > handshake lines controlled by the TINI. J3 on the other hand shows > control over all handshake lines. > (I see the same Boot messages from J3) > > Also, I have confirmed JavaKit is toggling DTR line. Verify that pin 25 signal on module/socket SIMM connector is toggling with DTR. Verify that when connected to J6 that you see both TX and RX. Could TX to the board be cut off? Trace the TX signal to the socket connector. -Bryan -- -- Bryan Armstrong bryan.armstrong-6tN4nzCoH/[email protected] _______________________________________________ TINI mailing list TINI-6tN4nzCoH/[email protected] To UNSUBSCRIBE, edit your profile, or see list archives: http://lists.dalsemi.com/mailman/listinfo/tini