Re: CANBus Baud Rates

Vic <simranranee-/[email protected]>
Newsgroups gmane.comp.hardware.microcontrollers.tini
Message-ID <[email protected]>
Bryan

Does changing the crystal affect the clock,
performance or other parts of TINI's operation?

Instead of 14Mhz could I change to 18Mhz.

Why was 18.432Mhz chosen in the first place, if its
known to cause CAN speed issues. Is there a specific
subsystem that requires such frequency for proper
operation?

Regds
Jameel


--- Bryan Armstrong <bryan.armstrong-6tN4nzCoH/[email protected]>
wrote:
> Vic wrote:
> > I would like to find out if anyone had managed to
> get
> > the TINI400's CAN interface to a high baud rate
> like
> > 750k or 1Mbps? 
> > 
> > The API docs show some BRP,TSEG1/2 values for old
> > TINI390 and its respective baud rate, is there a
> > similar list or a baud rate calculator for
> Tini400?
> 
> You will have to change the crystal to get 1Mbit/s
> with less than 0.5% 
> error as required by Bosch.  14MHz will work.
> 
> The bit rate calculation is pretty much the same for
> any CAN controller. 
>   Define your tqu, TSEG1 and TSEG2 and you are done.
>  I have not used 
> any baud rate calculation software, but you may be
> able to find one on 
> the Internet.  For my use, I just iterated through
> all the combinations 
> of bit parameters and picked the bit rate and sample
> position I wanted.
> 
> -Bryan
> 
> -- 
> --
> Bryan Armstrong
> bryan.armstrong-6tN4nzCoH/[email protected]
> 
> 


__________________________________
Do you Yahoo!?
Yahoo! Mail SpamGuard - Read only the mail you want.
http://antispam.yahoo.com/tools