Re: p1.1/t2ex crashes app
john bogus <bogusemail98230-/[email protected]>
| Newsgroups | gmane.comp.hardware.microcontrollers.tini |
|---|---|
| Message-ID | <[email protected]> |
well it looks like this was a red herring..... problem seems to be the signal was coupling onto a adjacent rs232 signal causing a glitch on DSR and thus reseting the system. --- john bogus <bogusemail98230-/[email protected]> wrote: > I am trying to track down a problem I have with the > P1.1/t2ex pin. And was wondering if anyone had had > any similar problems or any idea what could be > causing the problem. > > I am using the P1.1/T2EX pin for monitoring an rs232 > control signal. > > If I monitor p1.1 It properly follows the status of > the > p1.1 pin. p1.1 pin has a high input on it, the p1.1 > port reads 1, p1.1 pin has a low on it p1.1 reads > low. > If however I rapidly change the state back and > forth > the tine crashes. > > I have checked the T2CON register and it is set to > 0x34 so the EXEN2 = 0 therefore I would not expect > the > P1.1 pin to cause anything to happen. > > Has anyone else had any similar experiences, or have > any advice on this > > __________________________________ > Do you Yahoo!? > Yahoo! Mail - More reliable, more storage, less spam > http://mail.yahoo.com > __________________________________ Do you Yahoo!? Yahoo! Mail - More reliable, more storage, less spam http://mail.yahoo.com _______________________________________________ TINI mailing list TINI-6tN4nzCoH/[email protected] To UNSUBSCRIBE, edit your profile, or see list archives: http://lists.dalsemi.com/mailman/listinfo/tini