Re: Using TCR1 on MPC5554
Celso Brites <[email protected]> Thu, 09 Nov 2006 18:32:52 -0200
| Newsgroups | gmane.comp.hardware.motorola.microcontrollers |
|---|---|
| Organization | Freescale Semiconductors |
| Message-ID | <[email protected]> |
Yes, you can read TCR1 value from register ETPUTCR1. Don't even have to run any code on the eTPU, just setup the clock source and prescaler on register ETPUTBCR. Regards, Celso Robert Morin wrote: > Hi, > > is it possible to use TCR1 on a eTPU (A or B) as a free-running > counter that can > be read by the CPU ? -- POPI Classification: (X) General Business Information ( ) Motorola and Freescale Internal Use Only ( ) Motorola and Freescale Confidential Proprietary Celso Brites Motorola - Semiconductor Products Sector BSTC - Rod SP-340 Jaguariuna - Brazil 13820-000 Tel +55-19-3847-8437 Fax +55-19-3847-8203