Re: Cluster stall issue going to switched cluster...
tmac <[email protected]>
| Newsgroups | gmane.comp.hardware.netapp |
|---|---|
| Message-ID | <CAL9X-_EFFHMj_0zoDWKs9kJhAUOoz6Dbrmyo_GvBgEvwSXKq1Q@mail.gmail.com> |
The CN1610s should be running EFOS 1.3.0.2 or 1.3.0.3 with ONTAP 9.7 And the Reference Configuration File (RCF) should be current (1.2). The Supported Optics include: 332-00363, AFBR-703SMZ-NA3, AFBR-703SMZ-NA4, AFBR-709SMZ-NA3, AFBR-709SMZ-NA4, PLRXPL-SC-S43NA1 and PLRXPL-SC-S43NA2 Anything is possible with unsupported Optics. Another test you could do....use the optics and try the point-to-point connections with Optics and fibers first. Replace both e0a ports, then e0c, then e0b and finally e0d. If the issue returns, then the blame could certainly be the optics. --tmac *Tim McCarthy, **Principal Consultant* *Proud Member of the #NetAppATeam <https://twitter.com/NetAppATeam>* *I Blog at TMACsRack <https://tmacsrack.wordpress.com/>* On Mon, Nov 9, 2020 at 11:37 AM Heino Walther <[email protected]> wrote: > Hi guys > > > > I just had a bad experience today when trying to convert my switchless > AFF8080 to a switched cluster using a pair of CN1610 switches. > > The two switches are about 100M from the AFF8080 so the round trip is of > cause increased from 0,5M to 200M. > > But I do not think this is the problem here? We of cause use MultiMode > fibers between the two DCs, and the fibers checks out and didn’t seem to > have any errors. > > > > I followed this guide to convert two ports at a time: > > https://library.netapp.com/ecm/ecm_download_file/ECMP1140535 > > > > And it seemed to work just great on the console 😉 > > I must admit that I didn’t down the CN1610 ports as described because you > also down the ports on the NetApp side, so it seems pointless to do it on > both sides… > > Other than that I followed the guide. > > > > As soon as I completed the migration, the users started to complain about > very slow access on both CIFS, NFS and iSCSI. > > > > We looked at the port stats of the link but there were no errors… and the > system seemed to serve data, just very much slower the normal… so we had > to bite the bullet and switch back again, and as soon as we were back to > the normal back2back cables, the system was normal again… > > > > Going through the logs I found this error on one of the four links… > > > > 11/9/2020 13:40:34 STOR01-01 ERROR netif.sfpNotSupported: The > SFP+ or QSFP+ module (FINISAR CORP. FTLF8528P3BCV-QL) installed in e0a > is not supported with this network interface. > > > > And I must admit that a non-netapp SFP+ module had found its way to my > stash 😉. The other SFP+ modules were the same PN but just with a “NA1” > at the end…. I’m not sure if this could cause this issue? > > I have seen poor performance when using a non-supported NIC in a NetApp, > but non-supported SFP+ module? > > Has anyone had issues like this? > > > > We are on ONTAP 9.7P7 and the CN1610 are running a quote old FW, but I > have used them for other projects with no issues (i.e. multi node NetApp > clusters)… > > > > /Heino > _______________________________________________ > Toasters mailing list > [email protected] > https://www.teaparty.net/mailman/listinfo/toasters _______________________________________________ Toasters mailing list [email protected] https://www.teaparty.net/mailman/listinfo/toasters