Re: R6k and Ethernet current
"mario_wtbbh" <mario_wtbbh-/[email protected]>
| Newsgroups | gmane.comp.hardware.rabbit-semiconductor |
|---|---|
| Message-ID | <[email protected]> |
I'll grab an ethernet variant later today and will check. (Ours is permanently connected to a camera via an Ethernet x-over cable, so always has a connection). Long shot: Did you include the pulldown on Pin-7 (Lnk) "Needs ext pulldown on RCM5700/5750/6700/6750"? Regards, Mario --- In [email protected], "seecwriter" <seecwriter@...> wrote: > > For the RCM67XX module, we've noticed an anomaly with current draw > when using Ethernet. > > When the Ethernet port is connected to a LAN, the total current draw > for the computer section (motherboard + RCM67XX) is a steady 350ma. > However, if the Ethernet port is not connected, the current fluctuates > between 350ma and 500ma. We've traced the increase in current to the > call of pd_havelink() that occurs at about a 500ms rate. That 150ma of > extra current seems like a huge increase just to check for a LAN > connection. This pulsing current is affecting our ADC and DAC readings > and settings. > > This occurs on all of our modules. Anyone else notice this and/or have > any ideas on what to do about it? Adding extra bypass caps hasn't > helped. > > Steve >