Re: RCM3000 hardware problems

"Tom Collins tom-lnEA/wrDJtNWk0Htik3J/[email protected] [rabbit-semi]" <[email protected]> Wed, 20 Jan 2016 12:24:57 -0800
Newsgroups gmane.comp.hardware.rabbit-semiconductor
Message-ID <[email protected]>
Problems like this are often an indication of a grounding issue.  The programming cable provides a ground connection back to your computer.  Make sure your RS485 connections are set up correctly -- this page seems to imply that devices should share a common ground in addition to the differential voltage pair: http://www.chipkin.com/rs485-cables-why-you-need-3-wires-for-2-two-wire-rs485/

-Tom


On Jan 19, 2016, at 3:53 PM, 'Yang Hong' [email protected] [rabbit-semi] wrote:
> I am using BL4S200 with Modbus slave. I have some issue with USB-Serial (RS485) converter. As soon as I use debug port, I can easily and fast to connect BL4S200 via USB-Serial (RS485) converter to my pc application, however, when I download program into flash and remove programming cable from program port, It looks difficult to get connection with the same converter. Anybody has any clue?
> 
>