Re: net6501: doesn't start if not first unplugged for 8 minutes
Julien Cigar <[email protected]> Mon, 20 Mar 2017 17:49:33 +0100
| Newsgroups | gmane.comp.hardware.soekris.technical |
|---|---|
| Message-ID | <[email protected]> |
--===============1385716673== Content-Type: multipart/signed; micalg=pgp-sha512; protocol="application/pgp-signature"; boundary="fwqqG+mf3f7vyBCB" Content-Disposition: inline --fwqqG+mf3f7vyBCB Content-Type: text/plain; charset=utf-8 Content-Disposition: inline Content-Transfer-Encoding: quoted-printable On Mon, Mar 20, 2017 at 08:19:16AM -0700, EricB wrote: > On 3/20/2017 02:11, Julien Cigar wrote: > > On Mon, Mar 20, 2017 at 01:54:02AM +0100, Freek Dijkstra wrote: > >> On 20-03-2017 00:49, Jay Grizzard wrote: > >> > >>> I haven't fired up my 6501 to check the exact CPU model (...anyone wa= nt > >>> to buy it? It's of no use to me since Soekris never released the > >>> information needed to work with the FPGA), but I wonder if this could > >>> possibly be what's going on with them: > >>> https://www.theregister.co.uk/2017/02/06/cisco_intel_decline_to_link_= product_warning_to_faulty_chip/ > >> That article seems only related to the Intel Atom C2000. > >> The net6501 contains an older Intel Atom E640, single chip processor > >> with EG20T companion chip. > >> > >> Of course, that doesn't exclude the possibility that something similar > >> is the cause. > >> > >> At least the lesson I learned from Dries is that it really is related = to > >> the CPU, not to the power (as was previously suggested), and that it > >> might reboot if cooled down for a sufficiently long period of time. > >> > >> Well, mine stopped working last December after 5 years of operation as > >> my home router. I replaced it with something else (a Ubiquity > >> EdgeRouter), but I still had it lying around (mostly because I wanted = to > >> reuse to two mSATA disks, which seems uncommon these days) > >> > >> Well 3 months of cooling down should be sufficient, so I couldn't help > >> to check what happens if I fire it up again, and to my surprise, it did > >> boot all the way just a few seconds ago! > >> > >> Not that it matters much, I guess it still is a bit too unreliable to = my > >> taste. > > We bought 3 6501 2 years ago (for a redundant firewall/router + > > HAProxy). One of them died after a year, got replaced under warranty and > > died again 3 months later, another died just a few weeks agos, and the > > last one suffer from this puzzling "error led" problem (works until > > reboot, "sometimes" boot later, ...). > > > > I think there is definitively an hardware/BIOS issue with the board, I'm > > confident that the problem doesn't come from the power supply or an > > overheating from the CPU. > > > > As others I'm disappointed that Soekris is so silent on this issue, > > especially if the root cause doesn't come from a broken bios/PCB > > design/... > > > > As we run FreeBSD, we finally replaced those boxes with a RCC-VE 4860 1= U=20 > > from Netgate (https://www.netgate.com/products/rcc-ve-4860-1u.html) > I'm curious if ADI Engineering has addressed the issue that Intel > identifed with the RCC-VE. Also curious if those issues with the Intel > Avoton/C2000 chips is part of why the Soekris net6801 never went to > production... https://www.netgate.com/blog/clock-signal-component-issue.html I really hope it could be fixed with a BIOS upgrade or so... It's really strange, it looks exactly the same issue as for the 6501, but the chip is not listed as problematic in the Intel document...=20 (to be followed I guess ...) > > > >> Regards, > >> Freek > >> > >> _______________________________________________ > >> Soekris-tech mailing list > >> [email protected] > >> http://lists.soekris.com/mailman/listinfo/soekris-tech > > > > > > _______________________________________________ > > Soekris-tech mailing list > > [email protected] > > http://lists.soekris.com/mailman/listinfo/soekris-tech >=20 > _______________________________________________ > Soekris-tech mailing list > [email protected] > http://lists.soekris.com/mailman/listinfo/soekris-tech --=20 Julien Cigar Belgian Biodiversity Platform (http://www.biodiversity.be) PGP fingerprint: EEF9 F697 4B68 D275 7B11 6A25 B2BB 3710 A204 23C0 No trees were killed in the creation of this message. However, many electrons were terribly inconvenienced. --fwqqG+mf3f7vyBCB Content-Type: application/pgp-signature; name="signature.asc" -----BEGIN PGP SIGNATURE----- iQIzBAABCgAdFiEE7vn2l0to0nV7EWolsrs3EKIEI8AFAljQCBkACgkQsrs3EKIE I8CEUg//UtWIAT3HL2ux8JE/qpp7Vp+heU4DjSmA5CJ3Ow8uC1teUZ96xPBIQOon dlIp2lkUO8dne6DqM7T9XYrTMslIid9dH64Jpwy3ILR6SPGmB7ls250qi6Oo0lcb Od4XHEngH+BiwQQRwXfQmD3K7haKwUh1eJRh6VF97Zws3bOy1kH3xbEht2anRjOV qPFq6so5wRNQ/oOQUhMCaL4e3B35TukPHwLBdH1vy2LPptXla3X/fUVs3ZUfpdAh y9mJe72n1OoFiiY31GXqTFQpQL6bn9lT8FXyWypoDGg9yR97tIXY2SKwH4W1nJ2a BdOMwQ26AG66HE7GpqUF8nJPNqMznOrYTk7AYY9zV4nB8UfmEBjMqxLmxi1i6Sfo reindzssoH/JOZWo5O3Wvp9lS6b5IMCn4IZTYm/gMI+Rnhzc2yMhzQQCSz9hB7/3 UA6P4jMW8kmZrAQmR5R7vL3rinRgHOhoaeytOeneTS3xYb45DGVKuYm7rD+5ASof 2RXRD0bERegOhw5bC0Q84hwqWNpJ/qBHMSaoqOJIicQwG00U6Oq3BRkpCsMEpDHq nYfvZMJ7UL4AMhhYCxJDLlmgawxB0zS9t1xEu05qn9rg9y/JCoMnLdBj2TwuDbDO oBoPXF+W/J2QyHZhMJX3ykFdDkbeYnMJwQrrFnq+HKnjVEd+qOM= =dtlx -----END PGP SIGNATURE----- --fwqqG+mf3f7vyBCB-- --===============1385716673== Content-Type: text/plain; charset="us-ascii" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit Content-Disposition: inline _______________________________________________ Soekris-tech mailing list [email protected] http://lists.soekris.com/mailman/listinfo/soekris-tech --===============1385716673==--