Re: msp430-gdbproxy loses connection with target
Eric Decker <[email protected]>
| Newsgroups | gmane.comp.hardware.texas-instruments.msp430.gcc.user |
|---|---|
| Message-ID | <CAMdX_2B4qHP_-uJH40xtuv3DhZdZqTh28vEr0Y6BrVvds=xnbA@mail.gmail.com> |
have you verified that the board is getting the voltage that you think it should be? On Mon, Sep 2, 2013 at 3:38 PM, Andrew McLaren <[email protected]> wrote: > > > > On Tue, Aug 27, 2013 at 10:40:45AM +1200, Andrew McLaren wrote: > > > It would have been easy if the problem had been gdbproxy, > > but no such > > > luck. Now that mspdebug is running, I'm seeing exactly the same > > > scenario here. The messages are a tad different, but I > > think they are > > > saying the same thing. Everything works fine until mspdebug > > reports... > > > > > > fet: FET returned error code 18 (Could not determine device state) > > > fet: polling failed > > > > > > Once again, eveything appears hung outboard of mspdebug until the > > > target msp is repowered. If I simply try and restart > > mspdebug without > > > doing this, it will report; > > > > > > TI3410 device is in boot config, setting active > > > ti3410: TI_OPEN_PORT failed: A device attached to the system is not > > > functioning > > > ti3410: failed to set up port > > > > This looks like some kind of hardware problem. Have you tried > > different USB ports? > > > > Is the board powered externally, or does it draw power from the FET? > > > > Cheers, > > Daniel > > > > I've been having a bit of a play to try and isolate it, but haven't come up > with anything conclusive (or really anthing at all). > > To answer your questions > - the target board is powered by the FET > - I've tried switching USB ports, but no change. > > I've also tried switching the target processor (another 439), but also no > change. The only harware I haven't yet swapped out is the FET itself, but > only have the single TI FET running. I do have an Olimex FET here, but > having a few issues at present installing the drivers for that, so that is > the next step. > > The ONLY thing I have found so far that resets the problem is repowering > the > target MSP, which leads me to think that is must be some context in that > that is somehow being corrupted. I'd also like to try a different MSP > variant, but none of the others I have here have the ROM space this needs > (just thinking, I do have one of the TI experimeter boards around, and that > has a fairly hefty MSP on it, so that could be worth a go). > > So I have a couple of things to try. I'll keep you posted. > > Andrew > > -- Eric B. Decker Senior (over 50 :-) Researcher ------------------------------------------------------------------------------ Learn the latest--Visual Studio 2012, SharePoint 2013, SQL 2012, more! Discover the easy way to master current and previous Microsoft technologies and advance your career. Get an incredible 1,500+ hours of step-by-step tutorial videos with LearnDevNow. Subscribe today and save! http://pubads.g.doubleclick.net/gampad/clk?id=58040911&iu=/4140/ostg.clktrk _______________________________________________ Mspgcc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/mspgcc-users