Hi
is it possible to set an End gap penalty to false for Global alignment in biojava3.
As you can see, the T in biojava3 GA is wrong.
Needle gives correct result. In case of end gap penalty=true => same biojava3 result.
Thanks
khalil
Biojava3
query MGWSWIFLFLLSGTAGVLSEVQLQQSGPELVKPGASVRMSCKSSGYIFDDFYMNWVRQSHGKSLDYIGYISPYSGVTGYNQKFKGKATLTVDKSSSTAYMELRSLTSEDSAVYYCAGSSGNKWAMDYWGHGASVTVSS
target -------------------QVQLQQPGAELVKPGASVKLSCKASGYTF-----------------------------------------------------------------------------------------T
Needle (Emboss) : End gap penalty = false
query 1 MGWSWIFLFLLSGTAGVLSEVQLQQSGPELVKPGASVRMSCKSSGYIFDD 50
:|||||.|.|||||||||::|||:|||.|.
target 1 -------------------QVQLQQPGAELVKPGASVKLSCKASGYTFT- 30
query 51 FYMNWVRQSHGKSLDYIGYISPYSGVTGYNQKFKGKATLTVDKSSSTAYM 100
target 30 -------------------------------------------------- 30
query 101 ELRSLTSEDSAVYYCAGSSGNKWAMDYWGHGASVTVSS 138
target 30 -------------------------------------- 30
_______________________________________________
Biojava-l mailing list - [email protected]