Re: "logical attribute" problem

Simon Coulter <shc-Q/[email protected]> Wed, 27 Dec 2006 18:44:36 +1100
Newsgroups gmane.comp.lang.as400.mi
Message-ID <[email protected]>
On 27/12/2006, at 5:03 PM, S Bravo wrote:

> I have a little probleb with field's "logical attribute" - U 
> (Informational output text; function keys and options). The field with 
> this attribute is blinking on InfoWindow II, but not on CA workstation 
> screen.
> Can your help me to solve this "blinking" problem?

BLINK by itself only blinks on monochrome screens. To make text blink 
on colour screens you need both BLINK and HIGHLIGHT set on.

> And tell me some extra logical attributes (i have only some ... from 
> Leif's MI book).

Refer to the 5494 Functional Reference for the complete list of display 
attributes.


Regards,
Simon Coulter.
--------------------------------------------------------------------
    FlyByNight Software         AS/400 Technical Specialists

    http://www.flybynight.com.au/