Re: MI program unable to locate job - need assistance

"Robert Houts" <[email protected]> Tue, 13 May 2008 17:39:57 -0700
Newsgroups gmane.comp.lang.as400.mi
Message-ID <000c01c8b55b$09128840$1b3798c0$@net>
I'm not sure about V6R1 (or 6.1.0 as IBM now calls it), but up to V5R4 there
is still a maximum of 30 tables.  Each table can have a maximum of 16,352
jobs and the QMAXJOBS system value is limited to 485,000.  Thirty tables can
hold up to 490,560 jobs.  In the job table header object (QWCBT00) there is
a 2-byte binary field at offset 1CB (decimal offset 459) that contains the
count of tables.  On a system with 13 tables:

                              Display Job Tables
MYSYSTEM
                                                            05/13/08
17:05:58
Permanent job structures:                Temporary job structures:

  Initial  . . . . :   32767               Initial  . . . . :   16384

  Additional . . . :   500                 Additional . . . :   500

  Available  . . . :   57008               Available  . . . :   12999

  Total  . . . . . :   207557

  Maximum  . . . . :   391670

 

 

                         ---------------------Entries----------------------

     Table         Size        Total    Available       In-use        Other

         8     16752384        16352            0        16352            0

         9     16752384        16352         3454        12898            0

        10     16752384        16352        10332         6020            0

        11     16752384        16352        15539          813            0

        12     16752384        16352        16348            4            0

        13     11640576        11334        11334            0            0

 

 
Bottom


Dumping QWCBT00 reveals the following:

0001A0   00000000 00000000 00000000 00000000
0001C0   003C0000 0007F600 00000000 0D000000
0001E0   00008000 00000000 234BC6A4 A3000E38

The second line above shows x'000D' at offset 0001CB.  This is decimal
offset 459, or decimal position number 460 (hex position number 1CC).

I've checked this on at least 10 different systems (V5R2, V5R3, and V5R4)
with differing numbers of job tables and this field is definitely the count
of tables.

Using this field is the easiest way of ensuring that you will process all
tables.  To future-proof your code, make the array larger and use the table
count for your limit.



---wlteihnssf---
_______________________________________________
This is the MI Programming on the AS400 / iSeries (MI400) mailing list
To post a message email: MI400-Zwy7GipZuJhWk0Htik3J/[email protected]
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/mi400