Re: GP 2.2 INITIALIZE UPDATE (0x50) oddness

Sebastien Lorquet <[email protected]>
Newsgroups gmane.comp.lib.muscle
Message-ID <[email protected]>
You're obviously using a contact coupler in T=0 when I work daily with
contactless cards where Le does not matter :)

SELECT is a case 4 APDU so you have to send:

00A4 0400 00 67

or 00A4 0400 00 00
and the card will reply 6167

BR

Sébastien Lorquet

Le 20/09/2013 10:01, landyman70 a écrit :
> Sebastian,
> when I send 00A4040000 I get 6C67, so I sent 00A4040067 and the command
> failed... with a "Transaction failed." error.
> Hope that helps.
> 
> 
> 
> --
> View this message in context: http://musclecard.996296.n3.nabble.com/GP-2-2-INITIALIZE-UPDATE-0x50-oddness-tp5042p5048.html
> Sent from the MuscleCard mailing list archive at Nabble.com.
> 
> _______________________________________________
> Muscle mailing list
> [email protected]
> http://lists.musclecard.com/mailman/listinfo/muscle_lists.musclecard.com
>