Re: GP 2.2 INITIALIZE UPDATE (0x50) oddness
Sebastien Lorquet <[email protected]>
| Newsgroups | gmane.comp.lib.muscle |
|---|---|
| Message-ID | <[email protected]> |
You're obviously using a contact coupler in T=0 when I work daily with contactless cards where Le does not matter :) SELECT is a case 4 APDU so you have to send: 00A4 0400 00 67 or 00A4 0400 00 00 and the card will reply 6167 BR Sébastien Lorquet Le 20/09/2013 10:01, landyman70 a écrit : > Sebastian, > when I send 00A4040000 I get 6C67, so I sent 00A4040067 and the command > failed... with a "Transaction failed." error. > Hope that helps. > > > > -- > View this message in context: http://musclecard.996296.n3.nabble.com/GP-2-2-INITIALIZE-UPDATE-0x50-oddness-tp5042p5048.html > Sent from the MuscleCard mailing list archive at Nabble.com. > > _______________________________________________ > Muscle mailing list > [email protected] > http://lists.musclecard.com/mailman/listinfo/muscle_lists.musclecard.com >