access to SmartTerminal XX44

Vieri <[email protected]>
Newsgroups gmane.comp.lib.muscle
Message-ID <[email protected]>
Hi,


I'm having trouble accessing a smartcard (authentic driver - Cherry MY 8040 USB multiboard keyboard & reader).

pcsc_scan seems to see and identify the card correctly.

However,
I haven't tried anything else in Linux (like use the certificate within
the card to sign something or access a web site, etc.). In fact,
all I really want is to "redirect" the smartcard data to a Windows 2003 Terminal Server.
I use the following command from a Linux client:

rdesktop -r scard rdpserver

I even tried to set the device names accordingly:

rdesktop -r scard:"Cherry GmbH SmartTerminal XX44 00 00"="Cherry GmbH SmartTerminal XX44 0" -f "$RDP_SERVER"

I
can see that the reader is detected in Windows Terminal Server and that
it detects the events of inserting and removing a card.
However, 
when connecting with a Windows client, a user certificate is 
automatically installed in several apps (IE, etc.) whereas it's not if I
connect with a Linux rdesktop client.

I compared the 2 logs I 
get in the Windows 2003 Terminal Server (PC/SC diagnostics tool) when 
connecting with a Windows client and a Linux rdesktop client.
Basically,
when connected from Linux I get "Clock rate" and "BWT" errors. When 
connected from Windows Clock rate=4MHz and BWT=1439.48 work etu 
(actually these 2 values may vary if I connect from other Windows 
clients).

Here are the details (when connected with a Linux client):
Cherry GmbH SmartTerminal XX44 00 00: 

Attribute              |Value 
--------------------------------+---------------------------------------------- 
ATR            |3b fb 18 00 00 81 31 fe 45 00 31 c0 64 77 e9 10 00 01 90 00 62 
Clock rate (MHz)      |Error 
Convention         |direct 
Protocol         |T=1 
(TA1) Divider F         |372 
(TA1) Transfer factor D      |12 
(TB1) VPP supply      |unnecessary 
(TC1) Extra guardtime N      |0 work etu 
(TC2) Work waiting time      |115200 work etu 
(TA3) IFSC (byte)      |254 
(TB3) CWT         |43 work etu 
(TB3) BWT         |Error 
Historical Characters (text)   | 1Àdwé  
Historical Characters (hex)   |00 31 c0 64 77 e9 10 00 01 90 00 
 
I posted more debug information on the following forum:
http://forums.gentoo.org/viewtopic-t-986680.html

Below I'm specifying the support data asked for at http://pcsclite.alioth.debian.org/ccid.html#support:

Versions

    CCID driver version: 1.4.15
    pcsc-lite version: 1.8.11
    smart card reader name: Cherry GmbH SmartTerminal XX44
    the output of the command "/usr/sbin/pcscd --version": pcsc-lite version 1.8.11.
Copyright (C) 1999-2002 by David Corcoran <[email protected]>.
Copyright (C) 2001-2011 by Ludovic Rousseau <[email protected]>.
Copyright (C) 2003-2004 by Damien Sauveron <[email protected]>.
Report bugs to <[email protected]>.
Enabled
features: Linux i486-pc-linux-gnu serial usb libudev 
usbdropdir=/usr/lib/readers/usb ipcdir=/run/pcscd 
configdir=/etc/reader.conf.d


Platform

    Operating 
system or GNU/Linux distribution name and version: Linux 
3.10.32-std402-i586 #2 SMP Mon Feb 24 21:56:40 UTC 2014 i686 Intel(R) 
Atom(TM) CPU N450 @ 1.66GHz GenuineIntel GNU/Linux
 (custom system rescue CD based on Gentoo)
    Smart card middleware name and version: unknown/unused
    Reader manufacturer name and reader model name: Cherry MY 8040 USB (multiboard)
    Smart card name: unknown

Log

   
Attached log.txt (recorded while rdesktop connects to the Windows 
Terminal Server and the user removes and reinserts again the smartcard 
into the keyboard slot)

Any ideas?

Thanks,

Vieri