Re: DRBD Behavior on Device Failure, and Recovery Procedure

Gábor Hernádi <[email protected]>
Newsgroups gmane.comp.linux.drbd
Message-ID <CAL16tNZp=JEDeC=g9rQPs3sE97XQ=rfWza=vTDtyVZdcR7kjMQ@mail.gmail.com>
Hello,

As mentioned in the other drbd-user thread (Adding a Physical Disk to a
Storage Pool), this behaviour is controlled by LVM, not by Linstor. During
the `linstor sp c ...` command you only gave Linstor the name of the
volume-group, which is also what Linstor will use for the `lvcreate ...`
commands. If you want to control how LVM distributes the volumes within
that VG, you have to configure your VG accordingly, or use Linstor's
"StorDriver/LvcreateOptions"
property [1] to configure raid levels "per resource" (you can also set that
property on controller level which will affect all new resources).

> In such an event, what would be the recovery procedure? Swap the failed
drive, use vgcfrestore to restore the LVM data to the new PV, then do a
DRBD resync?

Sounds correct to me.

[1]
https://linbit.com/drbd-user-guide/linstor-guide-1_0-en/#s-storage-providers
-- 
Best regards,
Gabor Hernadi

_______________________________________________
Star us on GITHUB: https://github.com/LINBIT
drbd-user mailing list
[email protected]
https://lists.linbit.com/mailman/listinfo/drbd-user