Re: Linstor Resource Status Skip-Disk

Rene Peinthor <[email protected]> Mon, 19 Aug 2024 09:05:26 +0200
Newsgroups gmane.comp.linux.drbd
Message-ID <CAHmn2DMXMCrwm5m+USdScG31JQdvsjx-94sV3ciLeKTaMUGXag@mail.gmail.com>
--000000000000a2d6a4062003effd
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable

See:

https://linbit.com/drbd-user-guide/linstor-guide-1_0-en/#s-linstor-drbd-ski=
p-disk

Looks like your backend disk reported io-errors

On Thu, Aug 15, 2024 at 7:22=E2=80=AFPM Andreas Pflug <pgadmin@pse-consulti=
ng.de>
wrote:

> I'm running three nodes with DRBD9.1.18, two diskfull, one diskless, and
> Linstor 1.25.1.
> One of the storage nodes had a problem, after several reboots drbdadm
> status showed "diskless" on the node. drbdadm down res ; drbdadm up res
> resolved the situation, the status is UpToDate Secondary as expected agai=
n.
>
> Linstor still shows the resource as "UpToDate, Skip-Disk (R)" for that
> node. What does that mean, and how to reset that status? Restarting the
> satellite didn't help.
>
> Regards,
> Andreas
>

--000000000000a2d6a4062003effd
Content-Type: text/html; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable

<div dir=3D"ltr">See:<div><br></div><div><a href=3D"https://linbit.com/drbd=
-user-guide/linstor-guide-1_0-en/#s-linstor-drbd-skip-disk">https://linbit.=
com/drbd-user-guide/linstor-guide-1_0-en/#s-linstor-drbd-skip-disk</a><br><=
/div><div><br></div><div>Looks like your backend disk reported io-errors</d=
iv></div><br><div class=3D"gmail_quote"><div dir=3D"ltr" class=3D"gmail_att=
r">On Thu, Aug 15, 2024 at 7:22=E2=80=AFPM Andreas Pflug &lt;<a href=3D"mai=
lto:[email protected]">[email protected]</a>&gt; wrote:<br>=
</div><blockquote class=3D"gmail_quote" style=3D"margin:0px 0px 0px 0.8ex;b=
order-left:1px solid rgb(204,204,204);padding-left:1ex">I&#39;m running thr=
ee nodes with DRBD9.1.18, two diskfull, one diskless, and <br>
Linstor 1.25.1.<br>
One of the storage nodes had a problem, after several reboots drbdadm <br>
status showed &quot;diskless&quot; on the node. drbdadm down res ; drbdadm =
up res <br>
resolved the situation, the status is UpToDate Secondary as expected again.=
<br>
<br>
Linstor still shows the resource as &quot;UpToDate, Skip-Disk (R)&quot; for=
 that <br>
node. What does that mean, and how to reset that status? Restarting the <br=
>
satellite didn&#39;t help.<br>
<br>
Regards,<br>
Andreas<br>
</blockquote></div>

--000000000000a2d6a4062003effd--