RE: Re: referencing amplitude in VDLOAD subroutine

"David Lindeman [email protected] [Abaqus]" <[email protected]> Thu, 21 Feb 2019 15:16:46 +0000
Newsgroups gmane.comp.mathematics.abaqus.user
Message-ID <DM6PR03MB3435AF396683739FB9CD8667E17E0@DM6PR03MB3435.namprd03.prod.outlook.com>
One way is to use Python.  In the Python command window, use something like:

model = mdb.models[‘myModelName’]
numberOfNodes = 0
numberOfElements = 0
for key in model.parts.keys():
  part = model.parts[key]
  numberOfNodes += len(part.nodes)
  numberOfElements += len(part.elements)
print ‘Number of nodes =  ‘, numberOfNodes
print ‘Number of elements = ‘, numberOfElements

Note that you’ll need to adjust the logic if you have multiple instances of a dependent part, or if you’re using independent part instances (the mesh will be associated with the part instance, not the part, in that case).

Regards,

Dave Lindeman
Staff Scientist
Corporate Research Systems Laboratory
3M Center 235-3G-08
St. Paul, MN 55144
651-733-6383

From: [email protected] [mailto:[email protected]]
Sent: Thursday, February 21, 2019 1:36 AM
To: [email protected]
Subject: [EXTERNAL] Re: [Abaqus] referencing amplitude in VDLOAD subroutine


Hi, how can I find the number of elements or nodes in my model?

Many Thanks.



Sent from Yahoo Mail. Get the app<https://yho.com/148vdq>


On Friday, February 15, 2019, 7:55:59 PM GMT+8, David Lindeman [email protected] [Abaqus] <[email protected]> wrote:




The amplitude variation is defined using the *Amplitude keyword. The current value of the amplitude is passed into the subroutine and can be used in the calculation of the load.

Regards,

Dave Lindeman
Staff Scientist
Corporate Research Systems Laboratory
3M Center 235-3G-08
St. Paul, MN 55144
651-733-6383

From: [email protected] [mailto:[email protected]]
Sent: Wednesday, February 13, 2019 9:23 AM
To: [email protected]
Subject: [EXTERNAL] Re: [Abaqus] referencing amplitude in VDLOAD subroutine

Sir Thank you for replying
I wrote a subroutine VDLOAD for dynamic explicit analysis in ABAQUS. the load is spatially distributed as well as varying with time.
the spatial distribution works fine. For variation with time I made an amplitude in CAE module but it is not behaving as desired.
As in VDLOAD subroutine there is an amplitude variable which is un-modifiable.
i want to ask what is the use/function of that variable?
should i need to write codes for the variation with respect to time of 'press' or it will be done automatically ?

and in manual if we see in subroutine VDLOAD, in explanation it is written that the 'press' value should be multiplied by 'amplitude', Why?
I am attaching a google drive link of my simulation file please have a look...

https://drive...google.com/open?id=1NjGW4WMXryy0tf7yT3GBazU-FCbp55Am<https://drive.google.com/open?id=1NjGW4WMXryy0tf7yT3GBazU-FCbp55Am>

Thank you
Abhishek

On Wednesday, 13 February, 2019, 8:32:18 PM IST, Rami Ghorbel [email protected] [Abaqus] <[email protected]> wrote:

Dear Abhishek;
Did you link successfully your subroutine to Abaqus?

Le mar. 12 févr. 2019 à 13:51, abhishek [email protected]<mailto:[email protected]> [Abaqus] <[email protected]<mailto:[email protected]>> a écrit :
[Image removed by sender. Boxbe]<https://www.boxbe.com/overview>[Image removed by sender.]This message is eligible for Automatic Cleanup! ([email protected]<mailto:[email protected]>) Add cleanup rule<https://www.boxbe.com/popup?url=https%3A%2F%2Fwww.boxbe.com%2Fcleanup%3Fkey%3DZoib02NYleTecMww8nqCkTmfA2QSGJOVKgxyrOTgFJg%253D%26token%3DumPD8ca1%252Bxreh6eUl4GBGe9%252FKWOjFUizfBtn1lwzxqLtXvwcVLn%252FFA5pZDcl6qAt8tV03InurYSYPx7llvMvAIt2DaKBprlITYKvm6u6QAVnPJBCtHkgvLr4kRibCUFvM%252F7ALz2ZwQjZOFWFnywKJA%253D%253D&tc_serial=47901796961&tc_rand=978666046&utm_source=stf&utm_medium=email&utm_campaign=ANNO_CLEANUP_ADD&utm_content=001> | More info<http://blog.boxbe.com/general/boxbe-automatic-cleanup?tc_serial=47901796961&tc_rand=978666046&utm_source=stf&utm_medium=email&utm_campaign=ANNO_CLEANUP_ADD&utm_content=001>

Hello respected fellows

I am facing a problem in defining amplitude in VDLOAD subroutine. I am not able to understand as written in manual ' referencing amplitude', how to reference amplitude in VDLOAD subroutine?

Thank You
Abhishek

--
Cordialement;

Rami GHORBEL

Material Engineer

Phd Student

Phone : (00216) 22 667 771 / (00216) 54 007 770

________________________________

3M Notice: This communication is from an [EXTERNAL] sender.
If this email looks suspicious, do NOT click or open any links or attachments in the email. To report a suspicious email, click on the Report Phishing – PhishMe icon in the Outlook ribbon or forward this email using the report email as spam link in the text below..

Click here<https://spam.mmm.com/pem/pages/digestProcess/digestProcess.jsf?content=aedaaa864ecbae948fdbef283ccdd43058e917ac85dafafde283ec12dd5ec981c6c4ff5fb22097b592aab29dac82584f30f60c161a797f8d8d8a621478a2f25250f75f3a4b570e12125b08ef0dd8e5d1dbc7a045714a146255659761471276b9c37b570f20a98a734732948327931bff93d08ba9b6d561fef4856f1b6dd8aa1617d051a1b719785d> to report this email as spam

[Non-text portions of this message have been removed]





________________________________



3M Notice: This communication is from an [EXTERNAL] sender.
If this email looks suspicious, do NOT click or open any links or attachments in the email. To report a suspicious email, click on the Report Phishing – PhishMe icon in the Outlook ribbon or forward this email using the report email as spam link in the text below.

Click here<https://spam.mmm.com/pem/pages/digestProcess/digestProcess.jsf?content=aedaaa864ecbae945f2b83aecc7a2847e86ef067a05afcaa43f5ee7aa2d073f07f84f37f885629e2d9f11863505cd5960ac616536ee4e23285b2a4560df440260013180be7aa6b29f483d9656800ab8a0cef2d769bfa28fc3dd789610b0c2c2ab1612e40217e4b49e7e0466518f3f7b7856ddd2d979f14dda8a8b75179e396cd241719dcf5bbcade> to report this email as spam





[Non-text portions of this message have been removed]