| Newsgroups |
gmane.comp.mathematics.abaqus.user |
| Message-ID |
<[email protected]> |
Hello,
I am trying to simulate multi pass welding in Abaqus with subroutine, I have 3 passes, BEAD_1,BEAD_2,BEAD_3. I have problems when i run it, " An unterminated block exists."
i think i need to describe passes in the subroutine file. Could you please help me? what should i do?
my codes:
SUBROUTINE DFLUX(FLUX,SOL,KSTEP,KINC,
1 TIME1,NOEL,NPT,COORDS,JLTYP,TEMP,
1 PRESS, SNAME, BEAD_1,BEAD_2, BEAD_3)
c
INCLUDE 'ABA_PARAM.INC'
c
CHARACTER*80 SNAME
DIMENSION FLUX(2), TIME1(2), COORDS(3)
REAL t,X,Y,Z,VOLTAGE,CURRENT,VEL
t=TIME1(2)
EFF=1
RBAR=1
X=COORDS(1)
Y=Coords(2)
Z=Coords(3)
IF(SNAME.EQ."BEAD_1")THEN
IF(t.LE.15)THEN
CURRENT=690
VOLTAGE=42
VEL=7.
ELSEIF(SNAME.EQ."BEAD_2")THEN
IF((t.LE.26.AND.t.GE.16))THEN
CURRENT=751
VOLTAGE=33
VEL=5.
ELSEIF(SNAME.EQ."BEAD_3")THEN
IF(t.LE.37.AND.t.GE.27)THEN
CURRENT=751
VOLTAGE=33
VEL=5.
ENDIF
POWER=EFF*VOLTAGE*CURRENT
RBAR=1
VEL=7
X=COORDS(1)
HC=VEL*TIME1(2)
Z=COORDS(3)-HC
DIS=SQRT(X**2+Z**2)
FL1=3.0*POWER*EXP(-3.0*(DIS/RBAR)**2)
FL2=3.14*(RBAR**2)
FLUX(1)=FL1/FL2
RETURN
END
SUBROUTINE FILM(H,SINK,TEMP,KSTEP,KINC,
1 TIME1,NOEL,NPT,COORDS,JLTYP,FIELD,NFIELD,
1 SNAME, NODE,AREA)
c
INCLUDE 'ABA_PARAM.INC'
c
DIMENSION H(2),TIME1(2),COORDS(3)
CHARACTER*80 CMNAME
H(1)=((TEMP+273.1)**1.62)*21.69E-10
SINK=20.
RETURN
END