Re: Timer Interrupt Handler
Adam Lackorzynski <[email protected]>
| Newsgroups | gmane.comp.micro-kernel.l4.devel |
|---|---|
| Message-ID | <[email protected]> |
On Fri Jul 18, 2014 at 11:27:16 +0200, Xavier LEBARS wrote: > > -----Message d'origine----- > > De : l4-hackers [mailto:[email protected]] De la part > > de Adam Lackorzynski > > Envoyé : jeudi 17 juillet 2014 23:21 > > À : [email protected] > > Objet : Re: Timer Interrupt Handler > > Importance : Haute > > > > On Wed Jul 16, 2014 at 15:10:29 +0200, Xavier LEBARS wrote: > > > I'm always trying to configure the timer for my Zedboard and the > > > system clock doesn't advance. I checked this in the > > > Timer::system_clock() function > > > > > > > > > > > > In order to construct my timer driver, I use mptimer option, so I > > > configured the private timer of my board in the file > > > timer-arm-mptimer.cpp. Private Timers call the function interval() > > > which use the global timer of the board (bsp/zynq/ > > > timer-arm-mptimer-zynq.cpp > > > file) Here is a part of the implementation of my global timer (I just > > > launch counter) : > > > Mmio_register_block > > t(Kmem::mmio_remap(Mem_layout::Gpt_phys_base)); > > > t.write<Mword>(0, GPT_CR); > > > > > > t.write<Mword>(0, GPT_CNT0); > > > > > > t.write<Mword>(0, GPT_CNT1); > > > t.modify<Mword>(GPT_CR_EN, 0, GPT_CR); > > > Mword vc = start_as_counter(); > > > > > > while (t.read<Mword>(GPT_CNT0) < Gpt_ticks) > > > ; > > > Mword interval = (vc - stop_counter()) / Ticks; > > > > > > t.write<Mword>(0, GPT_CR); > > > > > > return interval; > > > > Is this calculating a proper interval value? For a start you can also just return a > > fixed value. > > With this configuration : > Timer_freq = 32768, > Ticks = 50, > > I obtain the following interval value : 85899345 That's far too large. > When I try to use a fixed value like in Tegra configuration (249 999 > or 499 999), I see no effects. Values must be in this range given the frequency the system uses. > > > The private timers are bind to the GIC with the IRQ 27, so I mentioned > > > this value in the static unsigned irq() function. > > > > Why 27 and not 29? > > A mistake between Global Timer Interrupts ID 27 and private timer interrupts ID 29 Ok. > > > Panic - Could not allocate scheduling IRQ 27 > > > > > > The origin of this problem is the allocate_irq() function > > > > > > So do I have to modify something in my IRQ manager or did I forget one > > > step during the construction of my timer driver ? Thanks in advance > > > > For the mptimer it should just work given a proper interval() value. > > So does the mptimer tick, i.e. reading the counter register multiple times > > gives a changing value everytime? Regarding the interrupt number, timer- > > arm-mptimer.cpp already has it defined. > > The counter register value change correctly It also wraps around? So there's no IRQ29. Does the UART IRQ work, i.e. entering JDB via ESC works (saying 'IRQ ENTRY')? Adam -- Adam [email protected] Lackorzynski http://os.inf.tu-dresden.de/~adam/