Re: [mh] relinking devices after PLM change?
Spencer Ryan <[email protected]>
| Newsgroups | gmane.comp.misc.misterhouse.user |
|---|---|
| Message-ID | <CALWY-Yqje3gHefVy56cct+0x+2U14Gn9_xVj+S=CDgBu+OnOMw@mail.gmail.com> |
Yes, but it's my understanding that I1/I2 devices required the set button to be pressed for linking. The I2CS devices basically implemented remote button press (in fact when you link them from the PLM they still chirp/beep like if you had pushed the physical button). It's not an overall increase in security (requiring you to know the device's ID helps only slightly) but it does allow you to replace your PLM or other controller and not have to go around and hit the button on every device, like ceiling fan controllers which may be difficult to get to. On Sun, Dec 6, 2020 at 2:19 PM Marc MERLIN <[email protected]> wrote: > On Sun, Dec 06, 2020 at 02:16:35PM -0500, Spencer Ryan wrote: > > The Link command has to contain the destination device's ID otherwise the > > device ignores it, so you need to know it (or brute force 24 bits of ID) > > True, but with I1, don't you also need the device ID to know who to send > the command to? > Sorry if I'm being dumb and missing something > > Marc > -- > "A mouse is a device used to point at the xterm you want to type in" - > A.S.R. > > Home page: http://marc.merlins.org/ | PGP > 7F55D5F27AAF9D08 > ________________________________________________________ To unsubscribe from this list, go to: https://lists.sourceforge.net/lists/listinfo/misterhouse-users