Re: R: Siemens TC35
Stipe Tolj <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Organization | Wapme Systems AG |
| Message-ID | <[email protected]> |
Angelo Ginocchio wrote: > 2002-01-24 21:55:20 [6] DEBUG: AT2[/dev/ttyS0]: <-- OK > 2002-01-24 21:55:31 [6] DEBUG: AT2[/dev/ttyS0]: --> AT+CMGF=0^M > 2002-01-24 21:55:35 [6] ERROR: AT2[/dev/ttyS0]: Opening failed. Terminating > 2002-01-24 21:55:35 [6] DEBUG: Thread 6 (gw/smsc_at2.c:at2_device_thread) it seems sometimes the device runs out of timeout when issuing the +CMGF command and waiting for a reply. Can we tweak this in smsc_at2.c using device specific timeouts? Stipe [email protected] ------------------------------------------------------------------- Wapme Systems AG Münsterstr. 248 40470 Düsseldorf Tel: +49-211-74845-0 Fax: +49-211-74845-299 E-Mail: [email protected] Internet: http://www.wapme-systems.de ------------------------------------------------------------------- wapme.net - wherever you are