Re: Optional parameters in smpp pdu's?
Wartan Hachaturow <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <[email protected]> |
On Thu, Feb 21, 2002 at 10:33:33AM -0000, Ronan Derby wrote: > Are you connecting to a SEMA SMSC? Hmm. No idea, to be honest :) I've been just said it supports SMPP v3.4. But I'll ask. > If so, I would suggest trying to set the SMPP version to 0x33 > (SMPP v3.3) in smsc_smpp.c and rebuilding Kannel. That didn't helped, unfortunately :( > The SMPP spec is a little vague about the use > of the message payload functionality, it says to use it for messages > over a certain length, but it doesn't say that it can't be used > for smaller messages. The SEMA SMSC uses it for all messages (I think). Yeah, my smsc also use it for all messages (even those that are <160 octets). So the problem is still in question: are there any patches for optional smpp parameters support (e.g., message payloading, for example)? If not, will you be interested in adding such a support, and, maybe, give me some recommendations? (I have to write the patch this weekend, so it should be out shortly :). -- Regards, Wartan. echo "Your stdio isn't very std." -- Larry Wall in Configure from the perl distribution