AW: Kannel DNS Problem. "kannel 1.0.3"

Jörg Pommnitz <[email protected]>
Newsgroups gmane.comp.mobile.kannel.devel
Message-ID <[email protected]>
The content size gets negotiated between the phone
and the gateway. The entity itself is the compiled
WML code. Since you are using Kannel-1.0.3 it might
well be that the D2 gateway generates compacter WMLC
packets so that they fit into the 1800 bytes.

Regards
  Jörg

 > -----Ursprüngliche Nachricht-----
 > Von: Bjoern Buettner [mailto:[email protected]]
 > Gesendet am: Donnerstag, 28. Februar 2002 23:23
 > An: [email protected]
 > Betreff: Kannel DNS Problem. "kannel 1.0.3"
 > 
 > I've tried to connect the URL http://d2wap.de Siemens S35 
 > says "unsupported
 > content type"
 > Is there any DNS FQDN problem (Bug) with Kannel? FQDN are 
 > running fine!
 > How can I solve the problem ?
 > 
 > The D2 WAP GW has no problem. (Standard configuration with 
 > Siemens S35)
 > 
 > Why the mesg., why a limit to 1800 B ?
 > >2002-02-28 22:05:41 [11] WARNING: WSP: Entity at 
 > http://d2wap.de too large
 > (size 2235 B, limit >1800 B)
 > 
 > 
 > Thank you !
 > 
 > Bjoern
 > 
 > 
 > 
 > 
 > comp. debug mesg
 > ################
 > 2002-02-28 22:06:09 [12] WARNING: WSP: Entity at 
http://d2wap.de too large
(size 2235 B, limit 1800 B)
2002-02-28 22:06:09 [2] DEBUG: WSP: machine 0x81ca168, state CONNECTED,
event S_MethodResult_Req
2002-02-28 22:06:09 [2] DEBUG: WSP: method 6, state PROCESSING, event
S_MethodResult_Req
2002-02-28 22:06:09 [12] DEBUG: Thread 12 (gw/wap-appl.c:fetch_thread)
terminates.
2002-02-28 22:06:09 [2] DEBUG: WSP 1/6: New method state REPLYING
2002-02-28 22:06:09 [5] DEBUG: WTP: resp_machine 6, state RESULT_WAIT, event
TR_Result_Req.
2002-02-28 22:06:09 [2] DEBUG: WSP 1: New state CONNECTED
2002-02-28 22:06:09 [5] DEBUG: WTP_SEND: add_initiator_address
2002-02-28 22:06:09 [5] DEBUG: WTP 6: New state RESULT_RESP_WAIT
2002-02-28 22:06:10 [5] DEBUG: WTP: resp_machine 6, state RESULT_RESP_WAIT,
event RcvAck.
2002-02-28 22:06:10 [5] DEBUG: WTP 6: New state LISTEN
2002-02-28 22:06:10 [5] DEBUG: WTP: Destroying WTPRespMachine 0x81d3970 (6)
2002-02-28 22:06:10 [2] DEBUG: WSP: machine 0x81ca168, state CONNECTED,
event TR_Result_Cnf
2002-02-28 22:06:10 [2] DEBUG: WSP: method 6, state REPLYING, event
TR_Result_Cnf
2002-02-28 22:06:10 [2] DEBUG: WSP 1/6: New method state NULL_METHOD
2002-02-28 22:06:10 [2] DEBUG: Destroying WSPMethodMachine 6


kind regards

Vodafone TeleCommerce GmbH
Architecture & Engineering
Bjoern Buettner
Daniel Goldbach Str. 17-19
40880 Ratingen

Tel. +49 (0) 21 02 / 97 20 13
Fax +49 (0) 21 02 / 97 15 14

mailto:[email protected]
www.vodafone.com
www.vodafone-telecommerce.de
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.