Re: [PATCH] SMPP sequence_number
Nisan Bloch <[email protected]>
| Newsgroups | gmane.comp.mobile.kannel.devel |
|---|---|
| Message-ID | <[email protected]> |
Hi +1 from me.. well spotted... n At 11:27 AM 9/6/02 +0200, you wrote: >Hi all, > >Find attached a patch to set correctly the sequence_number field of the >PDU header. According to SMPP 3.3 and 3.4 specs, it must be in the 1-N >range, but currently it is in the 0-N range. > >This causes problems with one of our providers, wich refuses to ack our >first bind_transmitter (with a 0 sequence_number). > >Also attached is a bearerbox.log showing the problem. > >Angel Fradejas >Mediafusión España, S.A. >[email protected] >www.mediafusion.es >Tel. +34 91 252 32 00 >Fax +34 91 572 27 08